Full-arch prostheses from translucent zirconia: Accuracy of fit

被引:39
|
作者
Sachs, Caroline [1 ]
Groesser, Julian [1 ]
Stadelmann, Markus [2 ]
Schweiger, Josef [1 ]
Erdelt, Kurt [1 ]
Beuer, Florian [1 ]
机构
[1] Univ Munich, Dept Prosthodont, Munich, Germany
[2] Stadelmann Dent, Munich, Germany
关键词
Translucent zirconia; CAD/CAM; Fixed dental prosthesis; 14-Unit framework; Marginal fit; Internal fit; In vitro; FIXED DENTAL PROSTHESES; FUSED-TO-METAL; MARGINAL FIT; PARTIAL DENTURES; CERAMIC CROWNS; CLINICAL FIT; IN-VIVO; RESTORATIONS; ADAPTATION; RETAINERS;
D O I
10.1016/j.dental.2014.05.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aim of this study was to evaluate the marginal and internal fit of single crowns, compared to 14-unit frameworks made of translucent yttria-stabilized zirconia. We hypothesized that there is an influence of the type of restoration on the marginal and internal fit. Methods. Eight teeth (FDI locations 17, 15, 13, 11, 21, 23, 25 and 27) of a typodont maxillary model were provided with a chamfer preparation to accommodate a 14-unit prosthesis or four single crowns (SCs). Ten 14-unit fixed dental prostheses (FDPs) and 40 single crowns were fabricated using a computer aided design (CAD)/computer aided manufacturing (CAM) system with pre-sintered translucent yttria-stabilized zirconia blanks. The restorations were cemented onto twenty master dies, which were sectioned into four pieces each. Then, the marginal and internal fits were examined using a binocular microscope. In order to detect the differences between the two types of restorations a non-parameteric test (Mann-Whitney-U) was carried out; to detect differences between the abutment teeth and the abutment surfaces non-parametric tests (Kruskal-Wallis) and pairwise post hoc analyses (Mann-Whitney-U) were performed after testing data for normal distribution (method according to Shapiro-Wilk). Level of significance was set at 5%. Results. The mean (SD) marginal opening gap dimensions were 18iirn (14) for the single crowns and 29iirn (27) for the 14-unit FDPs (p <0.001). Abutment 21 of the FDPs showed statistical differences concerning the location of the teeth in both marginal and internal fit (p <0.001). The measured gaps (types I-IV) revealed statistical differences between all types, when comparing SCs to the FDPs (p <0.001). Signcance. Single crowns showed significantly better accuracy of fit, compared to the 14unit FDPs. However, both restorations showed clinically acceptable marginal and internal fit. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:817 / 823
页数:7
相关论文
共 50 条
  • [1] Accuracy of Successive Casts for Full-Arch Fixed Prostheses
    Dounis, Kiki S.
    Dounis, Georgia
    Ditmyer, Marcia M.
    Ziebert, Gerald J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (05) : 446 - 449
  • [2] In-vitro fit of experimental full-arch restorations made from monolithic zirconia
    Schwindling, Franz Sebastian
    Bechtel, Kevin Nikolas
    Zenthofer, Andreas
    Handermann, Rebecca
    Rammelsberg, Peter
    Rues, Stefan
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 258 - 264
  • [3] Digital Workflow for Implant Rehabilitation with Double Full-Arch Monolithic Zirconia Prostheses
    Papaspyridakos, Panos
    Chochlidakis, Konstantinos
    Kang, Kiho
    Chen, Yo-wei
    Alghfeli, Abdulla
    Kudara, Yukio
    Weber, Hans-Peter
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (06): : 460 - 465
  • [4] Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit
    Papaspyridakos, Panos
    Hirayama, Hiroshi
    Chen, Chun-Jung
    Ho, Chung-Han
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1099 - 1105
  • [5] Retrospective Cohort Evaluation of Full-Arch Zirconia Implant-Supported Fixed Prostheses
    Al-Tarawneh, Sandra
    Thalji, Ghadeer
    Shonberg, David
    Fayz, Lily
    Cooper, Lyndon
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 381 - +
  • [6] Reverse scan body: Complete digital workflow for double full-arch zirconia prostheses
    Papaspyridakos, Panos
    Castellanos, Lina
    Bedrossian, E. Armand
    Romeo, Davide
    Kudara, Yukio
    Chochlidakis, Konstantinos
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [7] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [8] Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses
    Barbin, Thais
    Silva, Leticia Del Rio
    Veloso, Daniele Valente
    Borges, Guilherme Almeida
    Camacho Presotto, Anna Gabriella
    Ricardo Barao, Valentim Adelino
    Groppo, Francisco Carlos
    Mesquita, Marcelo Ferraz
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (06): : 329 - 337
  • [9] Full-arch implant-supported monolithic zirconia fixed dental prostheses: An updated systematic review
    AlTarawneh, Sandra
    Thalji, Ghadeer
    Cooper, Lyndon
    [J]. INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (01) : 13 - 22
  • [10] Zirconia full-arch implant prostheses: Survival, complications, and prosthetic space dimensions with 115 edentulous jaws
    Papaspyridakos, Panos
    Sinada, Naif
    Ntovas, Panagiotis
    Barmak, Abdul Basir
    Chochlidakis, Konstantinos
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,