accuracy of fit;
connection type;
digital dentistry;
edentulous;
full-arch prostheses;
implant impressions;
EDENTULOUS PATIENTS;
COMPLICATIONS;
FRAMEWORKS;
DENTISTRY;
PASSIVITY;
MISFIT;
D O I:
10.1111/clr.12695
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose: The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). Materials and Methods: An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant-and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Results: Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). Conclusion: For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found.
机构:
Xiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R ChinaXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
Cheng, Jing
Zhang, Haidong
论文数: 0引用数: 0
h-index: 0
机构:
Peking Univ, Sch & Hosp Stomatol, Dept Periodontol, Beijing, Peoples R China
Natl Ctr Stomatol, Beijing, Peoples R China
Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R ChinaXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
Zhang, Haidong
Liu, Hailin
论文数: 0引用数: 0
h-index: 0
机构:
Jingpin Med Technol Beijing Co Ltd, Beijing, Peoples R ChinaXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
Liu, Hailin
Li, Junying
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biol & Mat Sci & Prosthodont, Sch Dent, Ann Arbor, MI USAXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
Li, Junying
Wang, Hom-Lay
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
Univ Michigan, Dept Periodont & Oral Med, Sch Dent, 1011 North Univ Ave, Ann Arbor, MI 48109 USAXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
Wang, Hom-Lay
Tao, Xian
论文数: 0引用数: 0
h-index: 0
机构:
Stomatol Hosp, Dept Prosthodont, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen Med Coll, Xiamen, Peoples R China
Xiamen Med Coll, Stomatol Hosp, Dept Prosthodont, 1309 Lvling Rd, Xiamen 361008, Fujian, Peoples R ChinaXiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
机构:
Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
Univ Rochester, Dept Prosthodont, Eastman Inst Oral Hlth, Rochester, NY USATufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
Papaspyridakos, Panos
Kim, Yong-Jeong
论文数: 0引用数: 0
h-index: 0
机构:
Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USATufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
Kim, Yong-Jeong
Finkelman, Matthew
论文数: 0引用数: 0
h-index: 0
机构:
Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA 02111 USATufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
Finkelman, Matthew
El-Rafie, Khaled
论文数: 0引用数: 0
h-index: 0
机构:
Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USATufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
El-Rafie, Khaled
Weber, Hans-Peter
论文数: 0引用数: 0
h-index: 0
机构:
Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USATufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
机构:
The Second Affiliated Hospital of Zhejiang University,Department of General DentistryThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Rundong Zhang
Ziyu Ge
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang University,International School of MedicineThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Ziyu Ge
Xinrui Lang
论文数: 0引用数: 0
h-index: 0
机构:
The Second Affiliated Hospital of Zhejiang University,Department of General DentistryThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Xinrui Lang
Bo Qiao
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Provincial People’s Hospital,undefinedThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Bo Qiao
Jiayi Chen
论文数: 0引用数: 0
h-index: 0
机构:
The Second Affiliated Hospital of Zhejiang University,Department of General DentistryThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Jiayi Chen
Baoding Ye
论文数: 0引用数: 0
h-index: 0
机构:
The Second Affiliated Hospital of Zhejiang University,Department of General DentistryThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry
Baoding Ye
Yanzhen Zhang
论文数: 0引用数: 0
h-index: 0
机构:
Hangzhou West Lake Stomatological Hospital,undefinedThe Second Affiliated Hospital of Zhejiang University,Department of General Dentistry