Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit

被引:36
|
作者
Papaspyridakos, Panos [1 ,2 ]
Hirayama, Hiroshi [1 ]
Chen, Chun-Jung [3 ]
Ho, Chung-Han [4 ]
Chronopoulos, Vasilios [2 ,5 ]
Weber, Hans-Peter [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA
[2] Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[3] Chi Mei Med Ctr, Dept Dent, Tainan, Taiwan
[4] Chi Mei Med Ctr, Dept Med Res, Tainan, Taiwan
[5] Griffith Univ, Sch Dent & Oral Hlth, Dept Restorat Dent, Gold Coast, Qld, Australia
关键词
accuracy of fit; connection type; digital dentistry; edentulous; full-arch prostheses; implant impressions; EDENTULOUS PATIENTS; COMPLICATIONS; FRAMEWORKS; DENTISTRY; PASSIVITY; MISFIT;
D O I
10.1111/clr.12695
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). Materials and Methods: An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant-and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Results: Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). Conclusion: For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found.
引用
下载
收藏
页码:1099 / 1105
页数:7
相关论文
共 50 条
  • [31] Fixed Full-Arch Implant-Supported Prostheses in a Patient with Epidermolysis Bullosa: A Clinical Case History Report
    Agustin-Panadero, Ruben
    Gomar-Vercher, Sonia
    Penarrocha-Oltra, David
    Guzman-Letelier, Marcelo
    Penarrocha-Diago, Miguel
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (01) : 33 - 36
  • [32] Strain Behavior of Implant-Supported Full-Arch Fixed Dental Prostheses Supported by Four or Five Implants
    Sbardelotto, Cristian
    Lapria Faria, Adriana Claudia
    Tiossi, Rodrigo
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 153 - 158
  • [33] Immediate implant placement in fresh sockets versus implant placement in healed bone for full-arch fixed prostheses with conventional loading
    Altintas, N. Y.
    Taskesen, F.
    Bagis, B.
    Baltacioglu, E.
    Cezairli, B.
    Senel, F. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 226 - 231
  • [34] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854
  • [35] Digital vs. conventional full-arch implant impressions: a comparative study
    Amin, Sarah
    Weber, Hans Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367
  • [36] Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study
    Grande, Francesco
    Celeghin, Giordano
    Gallinaro, Federica
    Mobilio, Nicola
    Catapano, Santo
    MINERVA DENTAL AND ORAL SCIENCE, 2023, 72 (04) : 168 - 175
  • [37] Angled implant brush for hygienic maintenance of full-arch fixed-implant rehabilitations: a pilot study
    Setti, Paolo
    Pesce, Paolo
    Dellepiane, Elena
    Bagnasco, Francesco
    Zunino, Paola
    Menini, Maria
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (05): : 340 - 354
  • [38] Effect of different maintenance time of torque application on detorque values of abutment screws in full-arch implant-supported fixed prostheses
    Al-Otaibi, Hanan Nejer
    AL-Fouzan, Afnan F.
    Al-Mufleh, Tamadher S.
    Labban, Nawaf
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 848 - 851
  • [39] Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys
    Mai, Hang-Nga
    Kwon, Tae-Yub
    Hong, Min-Ho
    Lee, Du-Hyeong
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [40] Worn denture teeth of a full-arch implant-supported fixed dental prosthesis: A technique to restore
    Goodrick, Adam M. M.
    Nadjmi, Sassan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (02): : 105 - 109