The importance of appropriate reporting and investigation of incidental findings on computed tomography attenuation correction images during myocardial perfusion scintigraphy

被引:4
|
作者
Delaney, Francis T. [1 ]
Gray, Emma L. [1 ]
Lee, Joseph C. [1 ,2 ]
机构
[1] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[2] Univ Queensland, Fac Med, Brisbane, Qld, Australia
关键词
Computed tomography attenuation correction; incidental findings; low-dose computed tomography; lung carcinoma; myocardial perfusion scintigraphy;
D O I
10.4103/wjnm.WJNM_19_18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a case of lung cancer incidentally detected as a pulmonary nodule on computed tomography attenuation correction (CTAC) images during myocardial perfusion scintigraphy (MPS). Unfortunately, the incidental lesion was not fully investigated following MPS report and had developed into metastatic lung carcinoma when diagnosed over 1 year later, with failure of subsequent emergent chemotherapy. The disease appeared to be localized when initially detected during MPS. This case highlights the importance and potential clinical value of routine review of CTAC images in MPS with appropriate reporting and further investigation of suspicious incidental findings. In addition, the importance of effective communication between nuclear medicine department and treating team is clear to ensure suspicious incidental findings are given sufficient credence and thoroughly investigated promptly to avoid adverse clinical outcomes.
引用
收藏
页码:74 / 76
页数:3
相关论文
共 50 条
  • [11] Prevalence of Noncardiac Findings on Low Dose Computed Tomography used for Attenuation Correction in Myocardial Perfusion Imaging with SPECT
    Husmann, L.
    Tatsugami, F.
    Aepli, U.
    Valenta, I.
    Veit-Haibach, P.
    Gaemperli, O.
    Herzog, B.
    Burkhard, N.
    Wyss, C. A.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S159 - S159
  • [12] Reevaluation of Computed Tomography-Based Attenuation Correction on Myocardial Perfusion Imaging Compared With Coronary Angiography Findings
    Bitarafan-Rajabi, Ahmad
    Ghorbani, Mahsa
    Rastgou, Fereydoon
    Hekmat, Sepideh
    Firoozabadi, Hassan
    Malek, Hadi
    Yaghoobi, Nahid
    IRANIAN HEART JOURNAL, 2023, 24 (03): : 15 - 23
  • [13] Attenuation correction for single photon emission computed tomography myocardial perfusion imaging
    Corbett J.R.
    Kritzman J.N.
    Ficaro E.P.
    Current Cardiology Reports, 2004, 6 (1) : 32 - 40
  • [14] Incidental Detection of a Pulmonary Adenocarcinoma on Low-Dose Computed Tomography Used for Attenuation Correction in Myocardial Perfusion Imaging With SPECT
    Husmann, Lars
    Tatsugami, Fuminari
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    CLINICAL NUCLEAR MEDICINE, 2010, 35 (09) : 751 - 752
  • [15] Coincidental findings in thoracic CT-scan aquired for attenuation correction in myocardial perfusion scintigraphy
    Benz, R. M.
    Maas, O. C.
    Zellweger, M.
    Forrer, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S185 - S185
  • [16] Computed tomography attenuation correction improves the risk stratification accuracy of myocardial perfusion imaging
    Ou, Xiaohong
    Jiang, Lisha
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Li, Lin
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (05) : 495 - 500
  • [17] Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    Bateman, TM
    Cullom, SJ
    SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) : 37 - 51
  • [18] Renal abnormalities as incidental findings on myocardial single photon emission computed tomography perfusion imaging
    Ghanbarinia, Afshin
    Chandra, Sweta
    Chhabra, Kiran
    Jain, Diwakar
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (07) : 588 - 592
  • [19] Unexpected 99mTc-tetrofosmin findings during myocardial perfusion scintigraphy: intraindividual comparison with PET/computed tomography
    Gratz, Stefan
    Kempke, Bendix
    Kaiser, Wolf
    Behr, Thomas M.
    Pfestroff, Andreas
    Hoeffken, Helmut
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (11) : 963 - 969
  • [20] Attenuation correction of myocardial SPECT studies using low resolution computed tomography images
    Tonge, CM
    Manoharan, M
    Lawson, RS
    Shields, RA
    Prescott, MC
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (03) : 231 - 237