The importance of appropriate reporting and investigation of incidental findings on computed tomography attenuation correction images during myocardial perfusion scintigraphy

被引:4
|
作者
Delaney, Francis T. [1 ]
Gray, Emma L. [1 ]
Lee, Joseph C. [1 ,2 ]
机构
[1] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[2] Univ Queensland, Fac Med, Brisbane, Qld, Australia
关键词
Computed tomography attenuation correction; incidental findings; low-dose computed tomography; lung carcinoma; myocardial perfusion scintigraphy;
D O I
10.4103/wjnm.WJNM_19_18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a case of lung cancer incidentally detected as a pulmonary nodule on computed tomography attenuation correction (CTAC) images during myocardial perfusion scintigraphy (MPS). Unfortunately, the incidental lesion was not fully investigated following MPS report and had developed into metastatic lung carcinoma when diagnosed over 1 year later, with failure of subsequent emergent chemotherapy. The disease appeared to be localized when initially detected during MPS. This case highlights the importance and potential clinical value of routine review of CTAC images in MPS with appropriate reporting and further investigation of suspicious incidental findings. In addition, the importance of effective communication between nuclear medicine department and treating team is clear to ensure suspicious incidental findings are given sufficient credence and thoroughly investigated promptly to avoid adverse clinical outcomes.
引用
收藏
页码:74 / 76
页数:3
相关论文
共 50 条
  • [21] SPECT Myocardial Perfusion Imaging Quantification in Obese Subjects: Influence of Attenuation Correction with Computed Tomography Attenuation Maps
    Stakhiv, O.
    Clarke, M.
    Aplin, M.
    Singh, N.
    Day, K.
    Dizdarevic, S.
    Jessop, M.
    Sousa, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S167 - S168
  • [22] Accurate localization of incidental findings on the computed tomography attenuation correction image: the influence of tube current variation
    Thompson, John
    Hogg, Peter
    Higham, Samantha
    Manning, David
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (02) : 180 - 184
  • [23] Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction
    Plachcinska, Anna
    Wlodarczyk, Michal
    Kovacevic-Kusmierek, Katarzyna
    Bienkiewicz, Malgorzata
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Kasprzak, Jaroslaw D.
    Peruga, Jan Z.
    Kusmierek, Jacek
    KARDIOLOGIA POLSKA, 2016, 74 (01) : 32 - 39
  • [24] Effect of Low Dose CT Attenuation Correction in the Incidence of Ischemia During Myocardial Perfusion Scintigraphy
    Pipikos, T.
    Vlachou, F.
    Nikaki, A.
    Koletti, L.
    Gogos, K.
    Dalianis, K.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S515 - S516
  • [25] Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT
    Lars Husmann
    Fuminari Tatsugami
    Ursina Aepli
    Bernhard A. Herzog
    Ines Valenta
    Patrick Veit-Haibach
    Ronny R. Buechel
    Aju P. Pazhenkottil
    Oliver Gaemperli
    Nina Burkhard
    Christophe A. Wyss
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2009, 25 : 859 - 865
  • [26] Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT
    Husmann, Lars
    Tatsugami, Fuminari
    Aepli, Ursina
    Herzog, Bernhard A.
    Valenta, Ines
    Veit-Haibach, Patrick
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Gaemperli, Oliver
    Burkhard, Nina
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08): : 859 - 865
  • [27] The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images
    Tonge, Christine M.
    Ellul, Gordon
    Pandit, Manish
    Lawson, Richard S.
    Shields, Robert A.
    Arumugam, Parthiban
    Prescott, Mary C.
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (11) : 843 - 852
  • [28] The importance of the incidental thyroid gland uptake during Tc-99m MIBI myocardial perfusion scintigraphy
    Karacavus, S.
    Ede, H.
    Sarikaya, S.
    Delibas, N.
    Kaya, E.
    Erbay, A. R.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2015, 19 (15) : 2781 - 2785
  • [29] An investigation of the utility of attenuation correction of myocardial perfusion images in patients of normal body mass index
    Tonge, C. M.
    Arumugam, P.
    James, J. M.
    Muthu, S.
    Shawgi, M.
    Lawson, R. S.
    Shields, R. A.
    Prescott, M. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S408 - S409
  • [30] SPECT Myocardial Perfusion Imaging Quantification in Obese Subjects: Influence of Adipose Tissue in the Attenuation Correction with Computed Tomography Attenuation Maps
    Melo, I.
    Stakhiv, O.
    Jessop, M.
    Begley, P.
    Dizdarevic, S.
    Sousa, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S143 - S144