The importance of appropriate reporting and investigation of incidental findings on computed tomography attenuation correction images during myocardial perfusion scintigraphy

被引:4
|
作者
Delaney, Francis T. [1 ]
Gray, Emma L. [1 ]
Lee, Joseph C. [1 ,2 ]
机构
[1] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[2] Univ Queensland, Fac Med, Brisbane, Qld, Australia
关键词
Computed tomography attenuation correction; incidental findings; low-dose computed tomography; lung carcinoma; myocardial perfusion scintigraphy;
D O I
10.4103/wjnm.WJNM_19_18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a case of lung cancer incidentally detected as a pulmonary nodule on computed tomography attenuation correction (CTAC) images during myocardial perfusion scintigraphy (MPS). Unfortunately, the incidental lesion was not fully investigated following MPS report and had developed into metastatic lung carcinoma when diagnosed over 1 year later, with failure of subsequent emergent chemotherapy. The disease appeared to be localized when initially detected during MPS. This case highlights the importance and potential clinical value of routine review of CTAC images in MPS with appropriate reporting and further investigation of suspicious incidental findings. In addition, the importance of effective communication between nuclear medicine department and treating team is clear to ensure suspicious incidental findings are given sufficient credence and thoroughly investigated promptly to avoid adverse clinical outcomes.
引用
收藏
页码:74 / 76
页数:3
相关论文
共 50 条
  • [31] Increased accuracy of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy using iterative reconstruction of images
    Stevic, Milos
    Vlajkovic, Marina
    VOJNOSANITETSKI PREGLED, 2016, 73 (05) : 469 - 471
  • [32] The Effect of Attenuation Correction to Determine Reversible Defects in Myocardial Perfusion Scintigraphy: Comparison With Coronary Artery Based Angiographic Findings.
    Semirgin, S. Ucak
    Sahin, M.
    Demircan, S.
    Yapici, O.
    Sahin, M. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S289 - S289
  • [33] Gated single-photon emission computed tomography myocardial perfusion imaging is superior to computed tomography attenuation correction in discriminating myocardial infarction from attenuation artifacts in men and right coronary artery disease
    Xin, Wenchong
    Yang, Xiaoyu
    Wang, Jianfeng
    Shao, Xiaoliang
    Zhang, Feifei
    Shi, Yunmei
    Liu, Bao
    Yu, Wenji
    Tang, Haipeng
    Wu, Zhifang
    Wang, Yuetao
    Zhou, Weihua
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (05) : 491 - 498
  • [34] Use of coronary calcium score scans from standalone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    Schepis, T.
    Gaemperli, O.
    Koepfli, P.
    Rueegg, C.
    Burger, C.
    Leschka, S.
    Desbiolles, L.
    Husmann, L.
    Alkadhi, H.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S129 - S129
  • [35] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Marvin Grossmann
    Andreas A. Giannopoulos
    Fabiola A. Bechtiger
    Michael Messerli
    Moritz Schwyzer
    Dominik C. Benz
    Ken Kudura
    Catherine Gebhard
    Christoph Gräni
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    Journal of Nuclear Cardiology, 2020, 27 : 228 - 237
  • [36] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Grossmann, Marvin
    Giannopoulos, Andreas A.
    Bechtiger, Fabiola A.
    Messerli, Michael
    Schwyzer, Moritz
    Benz, Dominik C.
    Kudura, Ken
    Gebhard, Catherine
    Graeni, Christoph
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (01) : 228 - 237
  • [37] A Free-response Evaluation Determining Value in the Computed Tomography Attenuation Correction Image for Revealing Pulmonary Incidental Findings: A Phantom Study
    Thompson, John D.
    Hogg, Peter
    Manning, David J.
    Szczepura, Katy
    Chakraborty, Dev P.
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 538 - 545
  • [38] Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
    Tomoko Takamura
    Yoriko Horiguchi
    Masahiko Kanna
    Hirooki Matsushita
    Yuta Sudo
    Shinnosuke Kikuchi
    Tomohiro Ueda
    Ryo Sasaki
    Yukiko Morita
    Annals of Nuclear Medicine, 2015, 29 : 890 - 896
  • [39] Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
    Takamura, Tomoko
    Horiguchi, Yoriko
    Kanna, Masahiko
    Matsushita, Hirooki
    Sudo, Yuta
    Kikuchi, Shinnosuke
    Ueda, Tomohiro
    Sasaki, Ryo
    Morita, Yukiko
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (10) : 890 - 896
  • [40] Applicability of ultra-low dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Grossmann, M.
    Bechtiger, F.
    Giannopoulos, A. A.
    Messerli, M.
    Benz, D. C.
    Pazhenkottil, A. P.
    Gaemperli, O.
    Kaufmann, P. A.
    Buechel, R. R.
    EUROPEAN HEART JOURNAL, 2017, 38 : 625 - 626