Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
下载
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [1] The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images
    Tonge, Christine M.
    Ellul, Gordon
    Pandit, Manish
    Lawson, Richard S.
    Shields, Robert A.
    Arumugam, Parthiban
    Prescott, Mary C.
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (11) : 843 - 852
  • [2] Our Initial Experience With Attenuation Correction of Myocardial SPECT Using Low Resolution Computed Tomography of Hybrid SPECT/CT
    Hsieh, J.
    Lee, C.
    Wu, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S251 - S252
  • [3] A method for attenuation and scatter correction of brain SPECT based on computed tomography images
    Larsson, A
    Johansson, L
    Sundström, T
    Åhlström, KR
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) : 411 - 420
  • [4] Prevalence of Noncardiac Findings on Low Dose Computed Tomography used for Attenuation Correction in Myocardial Perfusion Imaging with SPECT
    Husmann, L.
    Tatsugami, F.
    Aepli, U.
    Valenta, I.
    Veit-Haibach, P.
    Gaemperli, O.
    Herzog, B.
    Burkhard, N.
    Wyss, C. A.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S159 - S159
  • [5] Attenuation correction in myocardial SPECT using multislice computed tomography-derived attenuation maps from coronary calcium scoring
    Schepis, T. S.
    Gaemperli, O. G.
    Ruesch, C. R.
    Namdar, M. N.
    Koepfli, P. K.
    Siegrist, P. S.
    Kaufmann, P. K.
    EUROPEAN HEART JOURNAL, 2006, 27 : 286 - 286
  • [6] Attenuation correction of myocardial SPECT studies - Reply
    Tonge, Christine M.
    Manoharan, Muthuvelu
    Lawson, Richard S.
    Shield, Robert A.
    Prescott, Mary C.
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (10) : 929 - 930
  • [7] SPECT Myocardial Perfusion Imaging Quantification in Obese Subjects: Influence of Attenuation Correction with Computed Tomography Attenuation Maps
    Stakhiv, O.
    Clarke, M.
    Aplin, M.
    Singh, N.
    Day, K.
    Dizdarevic, S.
    Jessop, M.
    Sousa, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S167 - S168
  • [8] The Influence Of Low- Dose CT Attenuation Correction On Artefacts Of Myocardial SPECT Images For Nuclear Medicine Studies
    Nolan, L.
    Seane, E.
    Du Toit, M.
    Lackay, C.
    Morkel, M.
    Korowlay, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S536 - S536
  • [9] Incidental Detection of a Pulmonary Adenocarcinoma on Low-Dose Computed Tomography Used for Attenuation Correction in Myocardial Perfusion Imaging With SPECT
    Husmann, Lars
    Tatsugami, Fuminari
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    CLINICAL NUCLEAR MEDICINE, 2010, 35 (09) : 751 - 752
  • [10] Lung Cancers Detected on Computed Tomography Attenuation Correction Images During Myocardial Perfusion Scintigraphy
    Tamura, Tomohiro
    Ojima, Eiji
    Satoh, Hiroaki
    CLINICAL LUNG CANCER, 2018, 19 (05) : E709 - E709