Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [41] Are attenuation correction and resolution recovery alone enough for thallium 201 spect studies?
    Genin, R
    Daou, D
    Delahaye, N
    Lebtahi, R
    Sarda, L
    Helal, BO
    Le Guludec, D
    Faraggi, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1065 - 1065
  • [42] Attenuation correction of myocardial SPECT perfusion images with low-dose CT: Evaluation of the method by comparison with perfusion PET
    Fricke, E
    Fricke, H
    Weise, R
    Kammeier, A
    Hagedorn, R
    Lotz, N
    Lindner, O
    Tschoepe, D
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 736 - 744
  • [43] DUAL ENERGY ATTENUATION CORRECTION FOR SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT)
    NALCIOGLU, O
    BOR, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 590 - 593
  • [44] Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    Schepis, Tiziano
    Gaemperli, Oliver
    Koepfli, Pascal
    Rueegg, Christine
    Burger, Cyrill
    Leschka, Sebastian
    Desbiolles, Lotus
    Husmann, Lars
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (01) : 11 - 19
  • [45] Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    Tiziano Schepis
    Oliver Gaemperli
    Pascal Koepfli
    Christine Rüegg
    Cyrill Burger
    Sebastian Leschka
    Lotus Desbiolles
    Lars Husmann
    Hatem Alkadhi
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 11 - 19
  • [46] Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography
    Caobelli, Federico
    Akin, Muharrem
    Thackeray, James T.
    Brunkhorst, Thomas
    Widder, Julian
    Berding, Georg
    Burchert, Ina
    Bauersachs, Johann
    Bengel, Frank M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) : 1036 - 1043
  • [48] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Marvin Grossmann
    Andreas A. Giannopoulos
    Fabiola A. Bechtiger
    Michael Messerli
    Moritz Schwyzer
    Dominik C. Benz
    Ken Kudura
    Catherine Gebhard
    Christoph Gräni
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    Journal of Nuclear Cardiology, 2020, 27 : 228 - 237
  • [49] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Grossmann, Marvin
    Giannopoulos, Andreas A.
    Bechtiger, Fabiola A.
    Messerli, Michael
    Schwyzer, Moritz
    Benz, Dominik C.
    Kudura, Ken
    Gebhard, Catherine
    Graeni, Christoph
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (01) : 228 - 237
  • [50] Computed tomography attenuation correction improves the risk stratification accuracy of myocardial perfusion imaging
    Ou, Xiaohong
    Jiang, Lisha
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Li, Lin
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (05) : 495 - 500