Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
下载
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [21] Measuring coronary artery calcification using positron emission tomography-computed tomography attenuation correction images
    Mylonas, Ilias
    Kazmi, Mustapha
    Fuller, Lyanne
    deKemp, Robert A.
    Yam, Yeung
    Chen, Li
    Beantands, Rob S.
    Chow, Benjamin J. W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (09) : 786 - 792
  • [22] Impact of CT-based attenuation and scatter correction on myocardial SPECT images
    van Dalen, J. A.
    Sellis, M.
    de Bruin, W. I.
    Wyndaele, D. N. J.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S286 - S286
  • [23] Attenuation correction in SPECT images reconstructed on multi-resolution point clouds
    Boutchko, Rostyslav
    Sitek, Arkadiusz
    Gullberg, Grant T.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4208 - +
  • [24] Attenuation correction and resolution recovery in thallium 201 SPECT studies.
    Genin, R
    Daou, D
    Girard, P
    Delahaye, N
    Lebtahi, R
    Sarda, L
    Helal, BO
    Le Guludec, D
    Faraggi, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 153P - 153P
  • [25] Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
    Tomoko Takamura
    Yoriko Horiguchi
    Masahiko Kanna
    Hirooki Matsushita
    Yuta Sudo
    Shinnosuke Kikuchi
    Tomohiro Ueda
    Ryo Sasaki
    Yukiko Morita
    Annals of Nuclear Medicine, 2015, 29 : 890 - 896
  • [26] Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
    Takamura, Tomoko
    Horiguchi, Yoriko
    Kanna, Masahiko
    Matsushita, Hirooki
    Sudo, Yuta
    Kikuchi, Shinnosuke
    Ueda, Tomohiro
    Sasaki, Ryo
    Morita, Yukiko
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (10) : 890 - 896
  • [27] Impact of computer tomography-attenuation correction on myocardial perfusion SPECT in a hybrid SPECT-CT
    Namdar, M
    Siegrist, PT
    Koepfli, P
    Tschütscher, P
    Kaufmann, PA
    EUROPEAN HEART JOURNAL, 2004, 25 : 637 - 638
  • [28] This clinical value of transmission attenuation correction (AC) in single proton emission computed tomography (SPECT) myocardial perfusion imaging.
    Fu, ZL
    Lin, JH
    Zhu, SL
    Zhu, M
    Wang, RF
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 86P - 87P
  • [29] Modeling of polychromatic attenuation using computed tomography reconstructed images
    Yan, CH
    Whalen, RT
    Beaupré, GS
    Yen, SY
    Napel, S
    MEDICAL PHYSICS, 1999, 26 (04) : 631 - 642
  • [30] Attenuation Correction in SPECT Images Using Attenuation Map Estimation with Its Emission Data
    Tavakoli, Meysam
    Naji, Maryam
    Abdollahi, Ali
    Kalantari, Faraz
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132