Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:70
|
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 50 条
  • [41] Comparison of Different Methods for Measurement of Shielding Fabrics Properties
    Szabo, Z.
    PIERS 2011 MARRAKESH: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 1144 - 1148
  • [42] Characterization of intraocular lenses: a comparison of different measurement methods
    Cherrier, M.
    Erichsen, I.
    Krey, S.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES III, 2010, 7556
  • [43] Comparison of three different methods of FeNO measurement in children
    Schiller, B.
    Barben, J.
    Hammer, J.
    Trachsel, D.
    SWISS MEDICAL WEEKLY, 2009, 139 (21-22) : 26S - 27S
  • [44] Comparison of different measurement methods of gas diffusion in the lung
    Preisser, Alexandra M.
    Seeber, Maxi
    Baur, Xaver
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [45] Measurement of cardiac output: Comparison of four different methods
    N Kothari
    A Hegde
    NV Mandke
    Indian Journal of Thoracic and Cardiovascular Surgery, 2003, 19 (4) : 163 - 168
  • [46] NITROGEN BALANCES - COMPARISON OF 3 DIFFERENT METHODS OF MEASUREMENT
    BERTRANDY, M
    GRIMAUD, D
    PHILIP, F
    DOLISI, C
    VELIN, P
    MAESTRACCI, P
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1983, 7 (02): : 210 - 211
  • [47] Comparison of different methods of time shift measurement in EEG
    Jiruska, P
    Proks, J
    Drbal, O
    Sovka, P
    Marusic, P
    Mares, P
    PHYSIOLOGICAL RESEARCH, 2005, 54 (04) : 459 - 465
  • [48] Comparison of three different polymerisation shrinkage measurement methods
    Klare, M
    Vogel, K
    Salz, U
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1283 - 1283
  • [49] Metacarpal Arc Motion: Comparison of Different Measurement Methods
    Bueren, Carina
    Al Maktary, Abdullah
    Windolf, Joachim
    Gehrmann, Sebastian, V
    JOURNAL OF HAND AND MICROSURGERY, 2022, 14 (01) : 79 - 84
  • [50] Diffusion Limitations of the Lung Comparison of Different Measurement Methods
    Preisser, A. M.
    Seeber, M.
    Harth, V.
    ENVIRONMENTAL BIOMEDICINE, 2015, 849 : 65 - 73