Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:70
|
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 50 条
  • [31] Assessment and comparison of different methods for heartbeat classification
    Jekova, I.
    Bortolan, G.
    Christov, I.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (02) : 248 - 257
  • [32] Comparison Of Different METHODS For Urine Hydration Assessment
    Ludwig, Anthony F.
    Rudolph, Chandler B.
    Evans, Hunter D.
    Erb, Noah J.
    Butts, Cory L.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 493 - 493
  • [33] In Vivo Assessment of Ascending and Arch Aortic Compliance
    Tobey, David J.
    Reynolds, Tyler S.
    Kopchok, George E.
    Donayre, Carlos E.
    Khoynezhad, Ali
    White, Rodney A.
    ANNALS OF VASCULAR SURGERY, 2019, 57 : 22 - 28
  • [34] Assessment of Myocardial Fibrosis Using Multimodality Imaging in Severe Aortic Stenosis Comparison With Histologic Fibrosis
    Park, Sung-Ji
    Cho, Sung Woo
    Kim, Sung Mok
    Ahn, Joonghyun
    Carriere, Keumhee
    Jeong, Dong Seop
    Lee, Sang-Chol
    Park, Seung Woo
    Choe, Yeon Hyeon
    Park, Pyo Won
    Oh, Jae K.
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 109 - 119
  • [35] SOMETIMES, MORE IS MORE: A CASE HIGHLIGHTING MULTIMODALITY IMAGING IN DETECTING ASCENDING AORTIC DISSECTION
    Paulraj, Shweta
    Kumar, Prashanth Ashok
    Uprety, Ajay
    Chaudhuri, Debanik
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 3055 - 3055
  • [36] Agreement in ascending aorta diameter measurement by multimodality imaging. Clinical implications
    Galuppo, V.
    Rodriguez-Palomares, J.
    Teixido, G.
    Gutierrez, L.
    Galian, L.
    Maldonado, G.
    Gonzalez-Alujas, M. T.
    Evangelista, A.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1195 - 1196
  • [37] NONINVASIVE MEASUREMENT OF ASCENDING AORTIC BLOOD VELOCITY IN MICE
    HARTLEY, CJ
    MICHAEL, LH
    ENTMAN, ML
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (01): : H499 - H505
  • [38] Ultrasound measurement of aortic diameters in rodent models of aneurysm disease
    Knipp, BS
    Ailawadi, G
    Sullivan, VV
    Roelofs, KJ
    Henke, PK
    Stanley, JC
    Upchurch, GR
    JOURNAL OF SURGICAL RESEARCH, 2003, 112 (01) : 97 - 101
  • [39] COMPARISON OF DIFFERENT METHODS FOR CONTACT-ANGLE MEASUREMENT
    UYAMA, Y
    INOUE, H
    ITO, K
    KISHIDA, A
    IKADA, Y
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1991, 141 (01) : 275 - 279
  • [40] Comparison of three different methods of ovarian reserve measurement
    Boyarsky, C
    Yartseva, A
    HUMAN REPRODUCTION, 1998, 13 : 163 - 163