Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:70
|
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 50 条
  • [21] COMPARISON OF DIFFERENT PH MEASUREMENT METHODS IN MEAT
    MAKIPETAYS, O
    KORKEALA, H
    ALANKO, T
    SORVETTULA, O
    ACTA VETERINARIA SCANDINAVICA, 1991, 32 (01) : 123 - 129
  • [22] COMPARISON OF 2 DIFFERENT METHODS OF OTF MEASUREMENT
    YEADON, EC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (04) : 501 - &
  • [23] A COMPARISON OF 2 DIFFERENT METHODS OF OTF MEASUREMENT
    YEADON, EC
    APPLIED OPTICS, 1969, 8 (12): : 2541 - &
  • [24] A comparison of different methods of spirometric measurement selection
    Koyama, H
    Nishimura, K
    Ikeda, A
    Tsukino, M
    Izumi, T
    RESPIRATORY MEDICINE, 1998, 92 (03) : 498 - 504
  • [25] Comparison of different eggshell thickness measurement methods
    Arslan, Abdulkadir
    Yamak, Umut Sami
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2020, 44 (05): : 1150 - 1153
  • [26] Comparison of different measurement methods for transmittance haze
    Yu, Hsueh-Ling
    Hsaio, Chin-Chai
    METROLOGIA, 2009, 46 (04) : S233 - S237
  • [27] Assessment of Aortic Stenosis Severity A Multimodality Approach
    Ternacle, Julien
    Clavel, Marie-Annick
    CARDIOLOGY CLINICS, 2020, 38 (01) : 13 - +
  • [28] Comparison of aortic valve dysfunction and ascending aorta dimension between patients with different bicuspid aortic valve morphology
    任心爽
    ChinaMedicalAbstracts(InternalMedicine), 2017, 34 (03) : 161 - 161
  • [29] 2 METHODS FOR MEASUREMENT OF ASCENDING AORTIC DIAMETER BY 2D ECHOCARDIOGRAPHY AS COMPARED WITH CINEANGIOGRAPHY
    MARX, GR
    GOLDBERG, SJ
    ALLEN, HD
    AMERICAN HEART JOURNAL, 1986, 112 (01) : 172 - 173
  • [30] COMPARISON OF DIFFERENT BLOOD PRESSURE ASSESSMENT METHODS
    Rodrigues, J.
    Freixa, M.
    Ferreira Simoes, A.
    Uria, S.
    Nunes Da Silva, G.
    JOURNAL OF HYPERTENSION, 2018, 36 : E177 - E177