Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:70
|
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 50 条
  • [11] Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis
    Smid, M.
    Ferda, J.
    Cech, J.
    Baxa, J.
    Hajek, T.
    Rokyta, R.
    EUROPEAN HEART JOURNAL, 2009, 30 : 207 - 207
  • [12] Dilatation of Vascular Prostheses in Ascending Aortic Position: A Long-Term Follow-Up Computed Tomography Study with Comparison of Different Measurement Methods
    Hamiko, Marwan
    Endlich, Matthias
    Kraemer, Christian
    Probst, Chris
    Welz, Armin
    Wilhelm, Kai
    Schiller, Wolfgang
    THORACIC AND CARDIOVASCULAR SURGEON, 2018, 66 (03): : 206 - 214
  • [13] Comparison of different measurement methods of cGMP
    Kremser, Marcel
    Winkler, Steffen
    Eitner, Frank
    Benardeau, Agnes
    Kraehling, Jan
    JOURNAL OF TRANSLATIONAL MEDICINE, 2019, 17 (01)
  • [14] Comparison of different measurement methods of magnetostriction
    Haraki, T
    Ishida, K
    Matsumura, Y
    Fujita, M
    Kuji, T
    Uchida, H
    SMART STRUCTURES, DEVICES, AND SYSTEMS, 2002, 4935 : 361 - 368
  • [15] Multimodality imaging and image guidance techniques for endovascular ascending aortic repair
    Katsarou, Maria
    Chinnadurai, Ponraj
    Bismuth, Jean
    Reardon, Michael J.
    JTCVS TECHNIQUES, 2022, 15 : 9 - 17
  • [16] Ascending Aortic Diameters in Congenital Aortic Stenosis: Cardiac Magnetic Resonance versus Transthoracic Echocardiography
    van der Linde, Denise
    Rossi, Alexia
    Yap, Sing C.
    McGhie, Jackie S.
    van den Bosch, Annemien E.
    Kirschbaum, Sharon W. M.
    Russo, Brunella
    van Dijk, Arie P. J.
    Moelker, Adriaan
    Krestin, Gabriel P.
    van Geuns, Robert-Jan M.
    Roos-Hesselink, Jolien W.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (05): : 497 - 504
  • [17] Bicuspid aortic valve, aortic dissection and sudden death in the young: Just a matter of ascending aorta diameters?
    Basso, Cristina
    Nistri, Stefano
    Rizzo, Stefania
    Abudureheman, Aierkeen
    Thiene, Gaetano
    CIRCULATION, 2007, 116 (16) : 463 - 463
  • [18] Formaldehyde Emissions from Wooden Toys: Comparison of Different Measurement Methods and Assessment of Exposure
    Even, Morgane
    Wilke, Olaf
    Kalus, Sabine
    Schultes, Petra
    Hutzler, Christoph
    Luch, Andreas
    MATERIALS, 2021, 14 (02) : 1 - 16
  • [19] Validation of intravascular ultrasound for measurement of aortic diameters: Comparison with multi-detector computed tomography
    Janosi, Rolf Alexander
    Gorla, Riccardo
    Rogmann, Kim
    Kahlert, Philipp
    Tsagakis, Konstantinos
    Dohle, Daniel-Sebastian
    Wendt, Daniel
    Jakob, Heinz
    Schlosser, Thomas
    Bossone, Eduardo
    Erbel, Raimund
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2015, 24 (05) : 289 - 295
  • [20] MEASUREMENT OF ASCENDING AORTIC FLOW PATTERNS IN MAN
    UTHER, JB
    PETERSON, KL
    SHABETAI, R
    BRAUNWAL.E
    JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (04) : 513 - 518