Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:70
|
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 50 条
  • [2] Multimodality assessment of aortic root and ascending aortic diameters in bicuspid aortic valves
    Vis, J. C.
    Rodriguez-Palomares, J. F.
    Teixido Tura, G.
    Gutierrez Garcia-Moreno, L.
    Gonzalez Alujas, T.
    Maldonado, G.
    Valente, F.
    Evangelista, A.
    EUROPEAN HEART JOURNAL, 2017, 38 : 285 - 285
  • [3] Variability in Echocardiographic Ascending Aortic Diameters due to Image Acquisition by Different Sonographers
    Bons, Lidia R.
    van den Hoven, Allard T.
    McGhie, Jackie S.
    van Berendoncks, An M.
    Wiegers-Groeneweg, Ellen J. A.
    van Haveren, Lourus W.
    Bowen, Dan J.
    van den Bosch, Annemien E.
    Cuypers, Judith A. A. E.
    Kauling, Robert M.
    Budde, Ricardo P. J.
    Roos-Hesselink, Jolien W.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (02) : 249 - +
  • [4] Comparison of different methods of determining retinal arteriolar diameters
    Chapman, N
    Witt, N
    Stanton, A
    Gau, X
    Thorn, S
    Hughes, A
    HYPERTENSION, 1999, 34 (04) : 704 - 704
  • [5] Direct measurement of ascending aortic diameter by intraoperative caliper assessment
    Vinholo, Thais Faggion
    Zafar, Mohammad A.
    Papanikolaou, Dimitra
    Chung, Juyeon
    Ellauzi, Hesham
    Ziganshin, Bulat A.
    Elefteriades, John A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (02): : E143 - E146
  • [6] Comparison of Aortic Diameters of Aviators
    Metin, Suleyman
    Cakmak, Tolga
    Ozturk, Cengiz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C129 - C130
  • [7] The analysis of ascending aortic dilatation in patients with a bicuspid aortic valve using the ratio of the diameters of the ascending and descending aorta
    Yuki Nakamura
    Masahiro Ryugo
    Fumiaki Shikata
    Masahiro Okura
    Toru Okamura
    Takumi Yasugi
    Hironori Izutani
    Journal of Cardiothoracic Surgery, 9
  • [8] The analysis of ascending aortic dilatation in patients with a bicuspid aortic valve using the ratio of the diameters of the ascending and descending aorta
    Nakamura, Yuki
    Ryugo, Masahiro
    Shikata, Fumiaki
    Okura, Masahiro
    Okamura, Toru
    Yasugi, Takumi
    Izutani, Hironori
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [9] Validity of the Sonographic Measurement of the Diameters of the Ascending Aorta in Rats
    Radu, C. N.
    Michineau, S.
    Hidalgo, A.
    Blanc, R.
    Gervais, M.
    Loisance, D. Y.
    Allaire, E.
    Kirsch, M.
    ULTRASCHALL IN DER MEDIZIN, 2010, 31 (01): : 26 - 30
  • [10] Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis
    Smid, Michal
    Ferda, Jiri
    Baxa, Jan
    Cech, Jakub
    Hajek, Tomas
    Kreuzberg, Boris
    Rokyta, Richard
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) : 152 - 155