CCMod: a GATE module for Compton camera imaging simulation

被引:19
|
作者
Etxebeste, A. [1 ]
Dauvergne, D. [2 ]
Fontana, M. [3 ]
Letang, J. M. [1 ]
Llosa, G. [4 ]
Munoz, E. [4 ]
Oliver, J. F. [4 ]
Testa, E. [3 ]
Sarrut, D. [1 ]
机构
[1] Univ Lyon 1, Univ Lyon, CREATIS, CNRS UMR5220,Inserm U1044,INSA Lyon, Lyon, France
[2] Univ Grenoble Alpes, LPSC, CNRS IN2P3 UMR 5821, Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS IN2P3 IP2I Lyon, F-69622 Villeurbanne, France
[4] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 05期
关键词
Monte Carlo; simulation; gamma imaging; Compton camera; ION-BEAM THERAPY; PERFORMANCE EVALUATION; RANGE VERIFICATION; PROTON-BEAMS; RESOLUTION; SYSTEM; MODEL; PET; OPTIMIZATION; SOFTWARE;
D O I
10.1088/1361-6560/ab6529
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13 degrees. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Design of a small laboratory Compton camera for the imaging of positron emitters
    Scannavini, MG
    Speller, RD
    Royle, GJ
    Cullum, I
    Raymond, M
    Hall, G
    Iles, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1155 - 1162
  • [42] Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera
    Roser, Jorge
    Barrientos, Luis
    Bello, Pilar
    Borja-Lloret, Marina
    Calatayud, Jose Manuel
    Casana, Jose V.
    Hueso-Gonzalez, Fernando
    Perez-Curbelo, Javier
    Prado, Stefan
    Ros, Ana
    Senra, Cesar
    Viegas, Rita
    Torres-Espallardo, Irene
    Llosa, Gabriela
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 132
  • [43] Design of a small laboratory Compton camera for the imaging of positron emitters
    Scannavini, M.G.
    Speller, R.D.
    Royle, G.J.
    Cullum, I.
    Raymond, M.
    Hall, G.
    Iles, G.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1120 - 1126
  • [44] Design Considerations Of A Compton Camera For Low Energy Medical Imaging
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Lazarus, I.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Simpson, J.
    INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES, 2009, 1194 : 90 - +
  • [45] Exact inversion of an integral transform arising in Compton camera imaging
    Terzioglu, Fatma
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [46] Application of Electron Tracking Compton Camera (ETCC) in Medical Imaging
    Sonoda, Shinya
    Ichimura, Yoshikatsu
    Kimura, Hiroyuki
    Kabuki, Shigeto
    Takada, Atsushi
    Mizmoto, Tetsuya
    Kubo, Hidetoshi
    Miyamoto, Shohei
    Komura, Shotaro
    Takemura, Taito
    Sawano, Tatsuya
    Kishimoto, Tetsuro
    Matsuoka, Yoshihiro
    Mizumura, Yoshitaka
    Tanimori, Toru
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [47] Analysis and simultion. for Compton camera's imaging resolution
    Song Zhang-Yong
    Yu De-Yang
    Cai Xiao-Hong
    ACTA PHYSICA SINICA, 2019, 68 (11)
  • [48] Compton-camera-based SPECT for thyroid cancer imaging
    Yu, Hengyong
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (01) : 111 - 124
  • [49] DEMONSTRATION OF 3-DIMENSIONAL IMAGING WITH A GERMANIUM COMPTON CAMERA
    MCKISSON, JE
    HASKINS, PS
    PHILLIPS, GW
    KING, SE
    AUGUST, RA
    PIERCEY, RB
    MANIA, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1221 - 1224
  • [50] Ultracompact Compton camera for innovative gamma-ray imaging
    Kataoka, J.
    Kishimoto, A.
    Taya, T.
    Mochizuki, S.
    Tagawa, L.
    Koide, A.
    Sueoka, K.
    Morita, H.
    Maruhashi, T.
    Fujieda, K.
    Kurihara, T.
    Arimoto, M.
    Okochi, H.
    Katsumi, N.
    Kinno, S.
    Matsunaga, K.
    Ikeda, H.
    Shimosegawa, E.
    Hatazawa, J.
    Ohsuka, S.
    Toshito, T.
    Kimura, M.
    Nagao, Y.
    Yamaguchi, M.
    Kurita, K.
    Kawachi, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 1 - 5