CCMod: a GATE module for Compton camera imaging simulation

被引:19
|
作者
Etxebeste, A. [1 ]
Dauvergne, D. [2 ]
Fontana, M. [3 ]
Letang, J. M. [1 ]
Llosa, G. [4 ]
Munoz, E. [4 ]
Oliver, J. F. [4 ]
Testa, E. [3 ]
Sarrut, D. [1 ]
机构
[1] Univ Lyon 1, Univ Lyon, CREATIS, CNRS UMR5220,Inserm U1044,INSA Lyon, Lyon, France
[2] Univ Grenoble Alpes, LPSC, CNRS IN2P3 UMR 5821, Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS IN2P3 IP2I Lyon, F-69622 Villeurbanne, France
[4] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 05期
关键词
Monte Carlo; simulation; gamma imaging; Compton camera; ION-BEAM THERAPY; PERFORMANCE EVALUATION; RANGE VERIFICATION; PROTON-BEAMS; RESOLUTION; SYSTEM; MODEL; PET; OPTIMIZATION; SOFTWARE;
D O I
10.1088/1361-6560/ab6529
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13 degrees. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Design of a small laboratory Compton camera for the imaging of positron emitters
    Univ Coll London, London, United Kingdom
    IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 1155 - 1162
  • [32] Gamma-ray Compton camera imaging with a segmented HPGe
    Schmid, GJ
    Beckedahl, DA
    Kammeraad, JE
    Blair, JJ
    Vetter, K
    Kuhn, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (03): : 565 - 576
  • [33] Study on the Imaging Resolution of a Multiply-stacked Compton Camera
    Kim, N. Y.
    Lee, J. H.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1409 - 1415
  • [34] Investigating the Impact of Secondaries Neutrons On Compton Camera for Medical Imaging
    Peterson, S.
    Maggi, P.
    Panthi, R.
    Mackin, D.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E632 - E632
  • [35] DESIGN OF A COMPTON CAMERA FOR IMAGING 662 KEV RADIONUCLIDE DISTRIBUTIONS
    ROYLE, GJ
    SPELLER, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 623 - 626
  • [36] Multi nuclides simultaneous imaging with the Electron Tracking Compton Camera
    Kabuki, Shiaeto
    Kubo, Hidetoshi
    Miuchi, Kentaro
    Kimura, Hiroyuki
    Amano, Hiroo
    Kawashima, Hidekazu
    Ueda, Masashi
    Nakamoto, Yuji
    Togashi, Kori
    Saji, Hideo
    Tanimori, Toru
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2008, 128 : 46 - 46
  • [37] Development of a Compton camera for prompt-gamma medical imaging
    Aldawood, S.
    Thirolf, P. G.
    Miani, A.
    Boehmer, M.
    Dedes, G.
    Gernhauser, R.
    Lang, C.
    Liprandi, S.
    Maier, L.
    Marinsek, T.
    Mayerhofer, M.
    Schaart, D. R.
    Lozano, I. Valencia
    Parodi, K.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 190 - 197
  • [38] Hodoscope Coincidence Imaging for Hadron Therapy Using a Compton Camera
    Gillam, J. E.
    Torres-Espallardo, I.
    Lacasta, C.
    Llosa, G.
    Barrio, J.
    Stankova, V.
    Solaz, C.
    Rafecas, M.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3508 - 3513
  • [39] Development of semiconductor imaging detectors for a Si/CdTe Compton camera
    Watanabe, Shin
    Takeda, Shin'ichiro
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Ushio, Masayoshi
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 871 - 877
  • [40] Low energy imaging using a prototype Compton camera.
    LeBlanc, JW
    Wehe, DK
    Wilderman, SJ
    Clinthorne, NH
    Rogers, WL
    Hua, C
    Weilhammer, P
    Nygard, E
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 173P - 173P