CCMod: a GATE module for Compton camera imaging simulation

被引:19
|
作者
Etxebeste, A. [1 ]
Dauvergne, D. [2 ]
Fontana, M. [3 ]
Letang, J. M. [1 ]
Llosa, G. [4 ]
Munoz, E. [4 ]
Oliver, J. F. [4 ]
Testa, E. [3 ]
Sarrut, D. [1 ]
机构
[1] Univ Lyon 1, Univ Lyon, CREATIS, CNRS UMR5220,Inserm U1044,INSA Lyon, Lyon, France
[2] Univ Grenoble Alpes, LPSC, CNRS IN2P3 UMR 5821, Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS IN2P3 IP2I Lyon, F-69622 Villeurbanne, France
[4] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 05期
关键词
Monte Carlo; simulation; gamma imaging; Compton camera; ION-BEAM THERAPY; PERFORMANCE EVALUATION; RANGE VERIFICATION; PROTON-BEAMS; RESOLUTION; SYSTEM; MODEL; PET; OPTIMIZATION; SOFTWARE;
D O I
10.1088/1361-6560/ab6529
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13 degrees. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Noise evaluation of Compton camera imaging for proton therapy
    Ortega, P. G.
    Torres-Espallardo, I.
    Cerutti, F.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J. F.
    Sala, P. R.
    Solevi, P.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 1845 - 1863
  • [22] Imaging of complex source fields with a Compton camera imager
    McKisson, JE
    Haskins, PS
    Henderson, DP
    Neelands, KC
    Wang, CK
    Evans, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 916 - 921
  • [23] A Compton camera prototype for prompt gamma medical imaging
    Thirolf, P. G.
    Aldawood, S.
    Boehmer, M.
    Bortfeldt, J.
    Castelhano, I.
    Dedes, G.
    Fiedler, F.
    Gernhaeuser, R.
    Golnik, C.
    Helmbrecht, S.
    Hueso-Gonzalez, F.
    Kolff, H. V. D.
    Kormoll, T.
    Lang, C.
    Liprandi, S.
    Lutter, R.
    Marinsek, T.
    Maier, L.
    Pausch, G.
    Petzoldt, J.
    Roemer, K.
    Schaart, D.
    Parodi, K.
    12TH INTERNATIONAL CONFERENCE ON NUCLEUS-NUCLEUS COLLISIONS 2015, 2016, 117
  • [24] A novel Compton camera with an annular absorber for enhancing the imaging efficiency in regions directly ahead: A simulation study
    Yuan, Ziquan
    Xue, Dongyang
    Yang, Hao
    Liu, Hansen
    Hua, Jianlang
    Wang, Haihao
    Jiang, Jianyong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2023, 60 (10) : 1208 - 1218
  • [25] An Electron-Tracking Compton imaging Camera based on a gaseous TPC and a scintillation camera
    Ueno, K.
    Hattori, K.
    Kabuki, S.
    Kubo, H.
    Kurosawa, S.
    Miuchi, K.
    Nagayoshi, T.
    Nishimura, H.
    Okada, Y.
    Orito, R.
    Takada, A.
    Tanimori, T.
    Tsuchiya, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1960 - +
  • [26] Compton Imaging Camera Using an Electron-Tracking Gaseous TPC and a Scintillation Camera
    Ueno, K.
    Hattori, K.
    Ida, C.
    Iwaki, S.
    Kabuki, S.
    Kubo, H.
    Kurosawa, S.
    Miuchi, K.
    Nishimura, H.
    Okada, Y.
    Takada, A.
    Takahashi, M.
    Tanimori, T.
    Tsuchiya, K.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2745 - +
  • [27] Gamma ray imaging with silicon detectors - a Compton camera for radionuclide imaging in medicine
    Solomon, Christopher John
    Ott, Robert John
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 787 - 792
  • [28] Astatine-211 imaging by a Compton camera for targeted radiotherapy
    Nagao, Yuto
    Yamaguchi, Mitsutaka
    Watanabe, Shigeki
    Ishioka, Noriko S.
    Kawachi, Naoki
    Watabe, Hiroshi
    APPLIED RADIATION AND ISOTOPES, 2018, 139 : 238 - 243
  • [30] A flexible geometry Compton camera for industrial gamma ray imaging
    Royle, GJ
    Speller, RD
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 821 - 824