Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera

被引:0
|
作者
Roser, Jorge [1 ,3 ]
Barrientos, Luis [1 ]
Bello, Pilar [2 ]
Borja-Lloret, Marina [1 ]
Calatayud, Jose Manuel [2 ]
Casana, Jose V. [1 ]
Hueso-Gonzalez, Fernando [1 ]
Perez-Curbelo, Javier [1 ]
Prado, Stefan [2 ]
Ros, Ana [1 ]
Senra, Cesar [1 ]
Viegas, Rita [1 ]
Torres-Espallardo, Irene [2 ]
Llosa, Gabriela [1 ]
机构
[1] UV, CSIC, Inst Fis Corpuscular IFIC, Valencia, Spain
[2] La Fe Hosp HUiP, Nucl Med Dept, Valencia, Spain
[3] Univ Lubeck, Inst Med Engn, Lubeck, Schleswig Holst, Germany
关键词
Compton cameras; Gamma cameras; Radiopharmaceutical imaging;
D O I
10.1016/j.ejmp.2025.104928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: The use of Compton cameras for imaging radioisotopes in nuclear medicine offers potential advantages over conventional gamma cameras in some aspects. In this work, we present the first results in this field with the Compton camera prototype MACACO III after a measurement campaign in La Fe Hospital (Valencia, Spain). Methods: Images of Derenzo-like phantoms filled with 18F-FDG and 131I-NaI have been obtained with MACACO III and, in the latter case, with gamma cameras available in the hospital. Subsequently, a metastatic lesion in a patient treated with 131I-NaI after thyroid gland resection was imaged. Results: The 18F-FDG phantom images show the prototype capability of identifying up to 4 mm diameter rods. The measurements with 131I-NaI-filled phantoms demonstrate the clear improvement of the spatial resolution attainable with MACACO III when compared with images obtained with the gamma cameras available in the hospital. Finally, the image of the patient metastatic lesion obtained with the Compton camera was found to be consistent with the gamma camera inspection image. Conclusion: These encouraging results demonstrate MACACO III's capability for radiopharmaceutical imaging and open a door for its application to nuclear medicine.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] System characterization and performance studies with MACACO III Compton camera
    Barrientos, L.
    Borja-Lloret, M.
    Casana, J. V.
    Hueso-Gonzalez, F.
    Ros, A.
    Roser, J.
    Senra, C.
    Solaz, C.
    Viegas, R.
    Llosa, G.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [2] Gamma-ray sources imaging and test-beam results with MACACO III Compton camera
    Barrientos, L.
    Borja-Lloret, M.
    Casana, J. V.
    Dendooven, P.
    Lopez, J. Garcia
    Hueso-Gonzalez, F.
    Jimenez-Ramos, M. C.
    Perez-Curbelo, J.
    Ros, A.
    Roser, J.
    Senra, C.
    Viegas, R.
    Llosa, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 117
  • [3] Performance evaluation of MACACO II Compton camera
    Barrientos, L.
    Borja-Lloret, M.
    Etxebeste, A.
    Munoz, E.
    Oliver, J. F.
    Ros, A.
    Roser, J.
    Senra, C.
    Viegas, R.
    Llosa, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
  • [4] Performance evaluation of MACACO: a multilayer Compton camera
    Munoz, Enrique
    Barrio, John
    Etxebeste, Ane
    Ortega, Pablo G.
    Lacasta, Carlos
    Oliver, Josep F.
    Solaz, Carles
    Llosa, Gabriela
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (18): : 7321 - 7341
  • [5] Compton Camera Imaging
    Ikeda, Shiro
    Odaka, Hirokazu
    Uemura, Makoto
    Takahashi, Tadayuki
    Watanabe, Shin
    Takeda, Shin'ichiro
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 674 - 677
  • [6] A Compton camera for multitracer imaging
    Yang, YF
    Gono, Y
    Motomura, S
    Enomoto, S
    Yano, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 656 - 661
  • [7] Compton-camera-based radiopharmaceutical imaging with an attenuation-corrected LM-MLEM reconstruction strategy
    Ren, Yuan
    Geng, Changran
    Yang, Xue
    Tang, Lijun
    Tian, Feng
    Tang, Xiaobin
    RADIATION MEASUREMENTS, 2025, 181
  • [8] Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection
    Munoz, Enrique
    Ros, Ana
    Borja-Lloret, Marina
    Barrio, John
    Dendooven, Peter
    Oliver, Josep F.
    Ozoemelam, Ikechi
    Roser, Jorge
    Llosa, Gabriela
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Radiopharmaceutical imaging based on 3D-CZT Compton camera with 3D-printed mouse phantom
    Tian, Feng
    Geng, Changran
    Yao, Zhiyang
    Wu, Renyao
    Xu, Jianfeng
    Cai, Fei
    Tang, Xiaobin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 140 - 148
  • [10] Author Correction: Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection
    Enrique Muñoz
    Ana Ros
    Marina Borja-Lloret
    John Barrio
    Peter Dendooven
    Josep F. Oliver
    Ikechi Ozoemelam
    Jorge Roser
    Gabriela Llosá
    Scientific Reports, 11