Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera

被引:0
|
作者
Roser, Jorge [1 ,3 ]
Barrientos, Luis [1 ]
Bello, Pilar [2 ]
Borja-Lloret, Marina [1 ]
Calatayud, Jose Manuel [2 ]
Casana, Jose V. [1 ]
Hueso-Gonzalez, Fernando [1 ]
Perez-Curbelo, Javier [1 ]
Prado, Stefan [2 ]
Ros, Ana [1 ]
Senra, Cesar [1 ]
Viegas, Rita [1 ]
Torres-Espallardo, Irene [2 ]
Llosa, Gabriela [1 ]
机构
[1] UV, CSIC, Inst Fis Corpuscular IFIC, Valencia, Spain
[2] La Fe Hosp HUiP, Nucl Med Dept, Valencia, Spain
[3] Univ Lubeck, Inst Med Engn, Lubeck, Schleswig Holst, Germany
关键词
Compton cameras; Gamma cameras; Radiopharmaceutical imaging;
D O I
10.1016/j.ejmp.2025.104928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: The use of Compton cameras for imaging radioisotopes in nuclear medicine offers potential advantages over conventional gamma cameras in some aspects. In this work, we present the first results in this field with the Compton camera prototype MACACO III after a measurement campaign in La Fe Hospital (Valencia, Spain). Methods: Images of Derenzo-like phantoms filled with 18F-FDG and 131I-NaI have been obtained with MACACO III and, in the latter case, with gamma cameras available in the hospital. Subsequently, a metastatic lesion in a patient treated with 131I-NaI after thyroid gland resection was imaged. Results: The 18F-FDG phantom images show the prototype capability of identifying up to 4 mm diameter rods. The measurements with 131I-NaI-filled phantoms demonstrate the clear improvement of the spatial resolution attainable with MACACO III when compared with images obtained with the gamma cameras available in the hospital. Finally, the image of the patient metastatic lesion obtained with the Compton camera was found to be consistent with the gamma camera inspection image. Conclusion: These encouraging results demonstrate MACACO III's capability for radiopharmaceutical imaging and open a door for its application to nuclear medicine.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Low energy imaging using a prototype Compton camera.
    LeBlanc, JW
    Wehe, DK
    Wilderman, SJ
    Clinthorne, NH
    Rogers, WL
    Hua, C
    Weilhammer, P
    Nygard, E
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 173P - 173P
  • [42] Design of a small laboratory Compton camera for the imaging of positron emitters
    Scannavini, MG
    Speller, RD
    Royle, GJ
    Cullum, I
    Raymond, M
    Hall, G
    Iles, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1155 - 1162
  • [43] Design of a small laboratory Compton camera for the imaging of positron emitters
    Scannavini, M.G.
    Speller, R.D.
    Royle, G.J.
    Cullum, I.
    Raymond, M.
    Hall, G.
    Iles, G.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1120 - 1126
  • [44] Design Considerations Of A Compton Camera For Low Energy Medical Imaging
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Lazarus, I.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Simpson, J.
    INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES, 2009, 1194 : 90 - +
  • [45] Exact inversion of an integral transform arising in Compton camera imaging
    Terzioglu, Fatma
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [46] Application of Electron Tracking Compton Camera (ETCC) in Medical Imaging
    Sonoda, Shinya
    Ichimura, Yoshikatsu
    Kimura, Hiroyuki
    Kabuki, Shigeto
    Takada, Atsushi
    Mizmoto, Tetsuya
    Kubo, Hidetoshi
    Miyamoto, Shohei
    Komura, Shotaro
    Takemura, Taito
    Sawano, Tatsuya
    Kishimoto, Tetsuro
    Matsuoka, Yoshihiro
    Mizumura, Yoshitaka
    Tanimori, Toru
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [47] Analysis and simultion. for Compton camera's imaging resolution
    Song Zhang-Yong
    Yu De-Yang
    Cai Xiao-Hong
    ACTA PHYSICA SINICA, 2019, 68 (11)
  • [48] Compton-camera-based SPECT for thyroid cancer imaging
    Yu, Hengyong
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (01) : 111 - 124
  • [49] DEMONSTRATION OF 3-DIMENSIONAL IMAGING WITH A GERMANIUM COMPTON CAMERA
    MCKISSON, JE
    HASKINS, PS
    PHILLIPS, GW
    KING, SE
    AUGUST, RA
    PIERCEY, RB
    MANIA, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1221 - 1224
  • [50] Ultracompact Compton camera for innovative gamma-ray imaging
    Kataoka, J.
    Kishimoto, A.
    Taya, T.
    Mochizuki, S.
    Tagawa, L.
    Koide, A.
    Sueoka, K.
    Morita, H.
    Maruhashi, T.
    Fujieda, K.
    Kurihara, T.
    Arimoto, M.
    Okochi, H.
    Katsumi, N.
    Kinno, S.
    Matsunaga, K.
    Ikeda, H.
    Shimosegawa, E.
    Hatazawa, J.
    Ohsuka, S.
    Toshito, T.
    Kimura, M.
    Nagao, Y.
    Yamaguchi, M.
    Kurita, K.
    Kawachi, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 1 - 5