Short communication: Kilovoltage measurement with rhodium target and filters on mammography X-ray machines

被引:3
|
作者
Underwood, AC
Law, J
Goodman, DA
Robinson, A
Rust, A
机构
[1] UNIV EDINBURGH,WESTERN GEN HOSP,DEPT MED PHYS & MED ENGN,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
[2] ADDENBROOKES HOSP,REG RADIAT PROTECT SERV,CAMBRIDGE CB3 7QJ,ENGLAND
[3] ST LUKES HOSP,REG RADIAT PROTECT SERV,GUILDFORD GU1 3NT,SURREY,ENGLAND
来源
BRITISH JOURNAL OF RADIOLOGY | 1996年 / 69卷 / 824期
关键词
D O I
10.1259/0007-1285-69-824-769
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray machines used for mammography have, until recently, almost exclusively employed molybdenum (Mo) as anode material and filtration. In the UK, the RMI model 232 kVp meter is used extensively for the measurement of kilovoltage on such equipment. This unit is provided with switchable internal calibration only for molybdenum and molybdenum, or tungsten and aluminium, as anode and filtration, respectively. However, rhodium (Rh) has recently been introduced for filtration with either a molybdenum or rhodium anode in mammography equipment but, as yet, calibration facilities are not available for rhodium spectra. In this work, appropriate corrections for readings obtained with the RMI 232 kVp meter are derived for use with rhodium as filtration material with either molybdenum or rhodium anode material. An intercomparison between measurements made with four RMI model 232 kVp meters and nine IGE DMR X-ray sets was undertaken. The reproducibility of the instruments was confirmed and measurements of tube potential made on each of the X-ray sets pooled. Measurements were made from a nominal 25-35 kVp using Mo/Mo, Mo/Rh and Rh/Rh target/filter combinations. Corrections for readings obtained with Mo/Rh and Rh/Rh were produced by comparison with readings obtained with Mo/Mo, assuming stability of tube potential between anodes. The results are compared with data recently produced by the manufacturer of the meter.
引用
收藏
页码:769 / 773
页数:5
相关论文
共 50 条
  • [31] X-RAY MAMMOGRAPHY - BACKGROUND TO A DECISION
    GREENBERG, DS
    NEW ENGLAND JOURNAL OF MEDICINE, 1976, 295 (13): : 739 - 740
  • [32] Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams
    Li, XA
    Ma, CM
    Salhani, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12): : 2561 - 2568
  • [33] Simulation of the Mammography X-ray Spectrum
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 271 - 274
  • [34] USE OF X-RAY SCREENS IN MAMMOGRAPHY
    STEVELS, ALN
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1977, 124 (03) : C110 - C110
  • [35] Portable X-ray machines
    Dondelinger, Robert
    Biomedical Instrumentation and Technology, 2006, 40 (02): : 139 - 144
  • [36] FLASH X-RAY MACHINES
    PASCHAL, FL
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (01): : 109 - &
  • [37] SPECTRAL DISTRIBUTION OF A THIN WINDOW RHODIUM TARGET X-RAY SPECTROGRAPHIC TUBE
    GILFRICH, JV
    BURKHALT.PG
    WHITLOCK, RR
    WARDEN, ES
    BIRKS, LS
    ANALYTICAL CHEMISTRY, 1971, 43 (07) : 934 - &
  • [38] MEASUREMENT OF INHERENT FILTRATION IN DIAGNOSTIC X-RAY TUBES AND EFFECT OF TARGET ANGLE ON X-RAY QUALITY
    ARDRAN, GM
    CROOKS, HE
    BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (536): : 599 - &
  • [39] Evaluate the effects of kilovoltage transmission target X-ray equipment combined with radiosensitizers for Auger electron radiotherapy
    Lin, Chin-Hsiung
    Feng, Chen-Ju
    Lai, Yuan-Chun
    Tseng, Shao-Chun
    Wu, Chin-Hui
    Hsu, Shih-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [40] Physical characteristics of the novel transmission-target X-ray equipment for kilovoltage radiation therapy applications
    Lin, Chin-Hsiung
    Wu, Chin-Hui
    Hsiao, Ching-Yu
    Chuang, Ho-Da
    Wu, Ni-Shan
    Feng, Chen-Ju
    Tseng, Shao-Chun
    Hsu, Shih-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2022, 197