Short communication: Kilovoltage measurement with rhodium target and filters on mammography X-ray machines

被引:3
|
作者
Underwood, AC
Law, J
Goodman, DA
Robinson, A
Rust, A
机构
[1] UNIV EDINBURGH,WESTERN GEN HOSP,DEPT MED PHYS & MED ENGN,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
[2] ADDENBROOKES HOSP,REG RADIAT PROTECT SERV,CAMBRIDGE CB3 7QJ,ENGLAND
[3] ST LUKES HOSP,REG RADIAT PROTECT SERV,GUILDFORD GU1 3NT,SURREY,ENGLAND
来源
BRITISH JOURNAL OF RADIOLOGY | 1996年 / 69卷 / 824期
关键词
D O I
10.1259/0007-1285-69-824-769
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray machines used for mammography have, until recently, almost exclusively employed molybdenum (Mo) as anode material and filtration. In the UK, the RMI model 232 kVp meter is used extensively for the measurement of kilovoltage on such equipment. This unit is provided with switchable internal calibration only for molybdenum and molybdenum, or tungsten and aluminium, as anode and filtration, respectively. However, rhodium (Rh) has recently been introduced for filtration with either a molybdenum or rhodium anode in mammography equipment but, as yet, calibration facilities are not available for rhodium spectra. In this work, appropriate corrections for readings obtained with the RMI 232 kVp meter are derived for use with rhodium as filtration material with either molybdenum or rhodium anode material. An intercomparison between measurements made with four RMI model 232 kVp meters and nine IGE DMR X-ray sets was undertaken. The reproducibility of the instruments was confirmed and measurements of tube potential made on each of the X-ray sets pooled. Measurements were made from a nominal 25-35 kVp using Mo/Mo, Mo/Rh and Rh/Rh target/filter combinations. Corrections for readings obtained with Mo/Rh and Rh/Rh were produced by comparison with readings obtained with Mo/Mo, assuming stability of tube potential between anodes. The results are compared with data recently produced by the manufacturer of the meter.
引用
下载
收藏
页码:769 / 773
页数:5
相关论文
共 50 条
  • [41] Evaluate the effects of kilovoltage transmission target X-ray equipment combined with radiosensitizers for Auger electron radiotherapy
    Lin, Chin-Hsiung
    Feng, Chen-Ju
    Lai, Yuan-Chun
    Tseng, Shao-Chun
    Wu, Chin-Hui
    Hsu, Shih-Ming
    Radiation Physics and Chemistry, 2024, 215
  • [42] Improvement of kilovoltage beam output with a transmission x-ray target: radiological optimization and cooling system design
    Acuna-Gomez, O. L.
    Garnica-Garza, H. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [43] Measurement of X-Ray Contamination From Metallic Filters in Electron Beams
    Lightfoot, D.
    Hartzell, S.
    MEDICAL PHYSICS, 2008, 35 (06) : 2750 - +
  • [44] X-RAY MONITOR FOR MEASUREMENT OF TITANIUM TRITIDE TARGET THICKNESS
    ALGER, DL
    STEINBERG, R
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (02): : 711 - +
  • [45] MEASUREMENT OF X-RAY INTENSITIES BY MEANS OF ROSS FILTERS AND PHOTOGRAPHIC FILMS
    MOTZFELD, V
    HERMS, G
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (03): : 296 - 298
  • [46] A Study On Output Factor Determination for Kilovoltage X-Ray Beams
    Kim, J.
    Mackonis, E. Claridge
    Hill, R.
    Kuncic, Z.
    MEDICAL PHYSICS, 2009, 36 (06) : 2582 - +
  • [47] Acceptance and commissioning of a modern kilovoltage X-ray therapy unit
    Aspradakis, M. M.
    Zucchetti, P.
    Seiler, R.
    Goetzfried, Th
    von Deschwanden, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 751 - 751
  • [48] In-Phantom Detector Response in a Kilovoltage X-Ray Beam
    Lawless, M.
    DeWerd, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 426 - +
  • [49] Evaluation of radiation dosimeters for kilovoltage x-ray beam dosimetry
    Hill, R.
    Me, Z.
    Haque, M.
    Baldock, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2336 - 2337
  • [50] METHOD OF CHECKING FILTRATION AND KILOVOLTAGE ON DIAGNOSTIC X-RAY TUBES
    PROCTER, NM
    BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (547): : 525 - 528