Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams

被引:33
|
作者
Li, XA
Ma, CM
Salhani, D
机构
[1] Ottawa Reg Canc Ctr, Dept Med Phys, Ottawa, ON K1Y 4K7, Canada
[2] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 12期
关键词
D O I
10.1088/0031-9155/42/12/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, nine commonly used dosimetry detectors have been investigated to determine suitable relative dosimeters for kilovoltage x-ray beams. By comparison with the Monte Carlo calculated data, it was determined that for the detectors studied the PTW N23342, Markus and NACP parallel-plate chambers are more suitable for the measurement of percentage depth dose (PDD) data for this beam quality range with an uncertainty of about 3%. A diode detector may be used to measure the PDD for the 100 kVp beam, but it is not suitable for higher energies (300 kVp). The Capintec parallel-plate chamber may be adequate for medium-energy photons, but it has a slightly higher uncertainty for low-energy x-rays (100 kVp). For the measurement of beam profiles, diode and film yield incorrect profile tails, which can be corrected using the RK ionization chamber.
引用
收藏
页码:2561 / 2568
页数:8
相关论文
共 50 条
  • [1] AN X-RAY TUBE MOUNTING FOR CONVERGENT BEAM THERAPY GIVING HIGH PERCENTAGE DEPTH DOSE
    KOLLIBAY, W
    BRITISH JOURNAL OF RADIOLOGY, 1950, 23 (275): : 653 - 655
  • [2] PERCENTAGE DEPTH DOSE FOR HIGH-ENERGY X-RAY BEAMS IN RADIOTHERAPY
    RAWLINSON, JA
    JOHNS, HE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1973, 118 (04) : 919 - 922
  • [3] Broad beam attenuation measurements in lead in kilovoltage X-ray beams
    Akber, Syed F.
    Das, Indra J.
    Kehwar, Than S.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (03): : 197 - 202
  • [4] SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS
    Araki, F.
    Umeno, S.
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (02) : 124 - 131
  • [5] Evaluation of Genipin Gel Dosimeter for Depth Dose Measurement of X-Ray Beams
    Gorjiara, T.
    Hill, R.
    Kuncic, Z.
    Baldock, C.
    MEDICAL PHYSICS, 2010, 37 (06) : 3274 - +
  • [6] Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06): : 1595 - 1615
  • [7] Estimation of X-Ray Energy Spectrum for CT Scanner from Percentage Depth Dose Measurement
    Hasegawa, Y.
    Haga, A.
    Sakata, D.
    Kanazawa, Y.
    Tominaga, M.
    Sasaki, M.
    Imae, T.
    Nakagawa, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E532 - E532
  • [8] Effective point of measurement of cylindrical ionization chambers in kilovoltage x-ray beams
    Hill, R.
    Healy, B.
    Tan, W.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1474 - S1474
  • [9] A Novel attachment system for cutouts in kilovoltage X-ray beam therapy
    Baumgartl, M.
    Kohler, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 872 - 872
  • [10] A novel attachment system for cutouts in kilovoltage x-ray beam therapy
    Baumgartl, M.
    Kohler, G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S813 - S813