Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [31] Comparison of macular thickness maps of a clinical SD-OCT and a low-cost self-administered OCT system
    Varcheie, Mahsa Darvishzadeh
    Bagherinia, Homayoun
    Fard, Ali
    Raden, Ian
    Callan, Thomas
    Rogoff, Bryan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [32] Comparison of the Abilities of SD-OCT and SS-OCT in Evaluating the Thickness of the Macular Inner Retinal Layer for Glaucoma Diagnosis
    Lee, Kyoung Min
    Lee, Eun Ji
    Kim, Tae-Woo
    Kim, Hyunjoong
    PLOS ONE, 2016, 11 (01):
  • [33] Reproducibility of Thickness Measurements of Macular Inner Retinal Layers Using SD-OCT With or Without Correction of Ocular Rotation
    Hirasawa, Hiroyo
    Araie, Makoto
    Tomidokoro, Atsuo
    Saito, Hitomi
    Iwase, Aiko
    Ohkubo, Shinji
    Sugiyama, Kazuhisa
    Ootani, Tomohiro
    Kishi, Shoji
    Matsushita, Kenji
    Maeda, Naoyuki
    Hangai, Masanori
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2562 - 2570
  • [34] Quantitative Comparison of Drusen Segmented on SD-OCT versus Drusen Delineated on Color Fundus Photographs
    Jain, Nieraj
    Farsiu, Sina
    Khanifar, Aziz A.
    Bearelly, Srilaxmi
    Smith, R. Theodore
    Izatt, Joseph A.
    Toth, Cynthia A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 4875 - 4883
  • [35] Retrospective comparison of mfERG and SD-OCT between RRMS and PPMS patients with and without optic neuritis
    Flowers, A. M.
    Adam, M. K.
    Sergott, R. C.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 359 - 360
  • [36] The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes
    Arintawati, Paramastri
    Sone, Takashi
    Akita, Tomoyuki
    Tanaka, Junko
    Kiuchi, Yoshiaki
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 713 - 718
  • [37] SD-OCT parameters and visual field defect in chiasmal compression and the diagnostic value of neural network model
    Jeon, Hyeshin
    Park, Keun-hyung
    Kim, Huikyung
    Choi, Heeyoung
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2738 - 2745
  • [38] Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range
    Miraftabi, Arezoo
    Amini, Navid
    Morales, Esteban
    Henry, Sharon
    Yu, Fei
    Afifi, Abdolmonem
    Coleman, Anne L.
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (11) : 4815 - 4823
  • [39] Comparison of SD-OCT with slit lamp grading of anterior chamber cell in a rabbit model of anterior uveitis
    Yuan, Alex
    Edmond, Michaela
    Bell, Brent A.
    Sharma, Amit
    DiCicco, Rose M.
    Tucker, Lauren
    Tao, Yuankai
    Srivastava, Sunil K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [40] Weakly supervised serous retinal detachment segmentation in SD-OCT images by two-stage learning
    Xing, Ruiwen
    Niu, Sijie
    Gao, Xizhan
    Liu, TIngting
    Fan, Wen
    Chen, Yuehui
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (04) : 2312 - 2327