The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes

被引:51
|
作者
Arintawati, Paramastri [1 ]
Sone, Takashi [1 ]
Akita, Tomoyuki [2 ]
Tanaka, Junko [2 ]
Kiuchi, Yoshiaki [1 ]
机构
[1] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Dept Epidemiol Infect Dis Control & Prevent, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
关键词
GCC; RNFL; preperimetric-perimetric glaucoma; OPTICAL COHERENCE TOMOGRAPHY; RETINAL NERVE-FIBER; LAYER THICKNESS; MACULAR VOLUME; VISUAL-FIELD; DOMAIN;
D O I
10.1097/IJG.0b013e318259b2e1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To determine whether the thicknesses of the different parameters of the ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer can be used to differentiate eyes with glaucoma from normal eyes.Methods:Two hundred sixty-one eyes, including 68 normal eyes and 32 preperimetric glaucoma, 81 early glaucoma, and 80 advanced glaucoma were analyzed in the present study. The thicknesses of the GCC and retinal nerve fiber layer were measured using RTVue spectral-domain optical coherence tomographic (SD-OCT) images. The area under the receiver operating characteristic (AUROC) curve and sensitivities at fixed specificities were calculated for each parameter. A logistic regression analysis was used to determine the risk factors for glaucoma.Results:The 2 largest AUROC curves for all glaucoma stages were those for the GCC parameters. The global loss volume (GLV) was always one of the 2 highest values of the AUROC curve. The GLV also had the highest sensitivity at a fixed specificity to identify glaucoma at early and advanced stage. The focal loss volume (FLV) had the largest AUROC curve value and the highest sensitivity at a fixed specificity for advanced glaucoma. The logistic regression analysis showed that the GLV was one of the factors that predicted preperimetric glaucoma [odds ratio (OR)=1.74] and early glaucoma (OR=1.22), whereas the FLV was useful for detecting advanced glaucoma (OR=2.32).Conclusions:The SD-OCT-derived macular GCC parameters can be used to detect preperimetric and perimetric glaucoma. The new GCC parameters, GLV and FLV, performed well in discriminating glaucomatous eyes from normal eyes.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [1] Glaucoma discrimination of ganglion cell complex measurements with two SD-OCT
    Francoz, Marlene
    El Chehab, Hussam
    Fenolland, Jean-Remi
    Delbarre, Maxime
    Giraud, Jean-Marie
    May, Frank
    Renard, Jean-Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Evaluation of the new Canon HS-100 SD-OCT: Reproducibility of macular ganglion cell complex (GCC) thickness measurement in normal, hypertensive and glaucomatous eyes
    Rosenberg, R.
    Marill, A. -F.
    Fenolland, J. -R.
    El Chehab, H.
    Delbarre, M.
    Marechal, M.
    Abayi, A. Mouinga
    Giraud, J. -M.
    Renard, J. -P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (09): : 832 - 843
  • [3] Ganglion cell complex measurement and glaucoma diagnosis using two SD-OCT
    Francoz, M.
    El Chehab, H.
    Fenolland, J. R.
    Delbarre, M.
    Marechal, M.
    Ouanezar, S.
    Giraud, J. M.
    May, F.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [4] Correction of the Retinal Angle in SD-OCT of Glaucomatous Eyes Provides Better Reproducibility of Optic Nerve Head Parameters
    Lee, Kyungmoo
    Kwon, Young
    Abramo, Michael
    Garvin, Mona
    Sonka, Milan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] SD-OCT peripapillary nerve fibre layer and ganglion cell complex parameters in glaucoma: principal component analysis
    Pazos, Marta
    Biarnes, Marc
    Blasco-Alberto, Andres
    Dyrda, Agnieszka
    Angel Luque-Fernandez, Miguel
    Gomez, Alicia
    Mora, Clara
    Milla, Elena
    Jesus Muniesa, Ma
    Anton, Alfonso
    Tinguaro Diaz-Aleman, Valentin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (04) : 496 - 501
  • [6] Layer by Layer Automated Retinal Segmentationwith SD-OCT in the Macula of Normal and Glaucomatous Eyes
    Pazos, Marta
    Anna Dyrda, Agnieszka
    Gomez, Alicia
    Martin, Carlos
    Anton-Lopez, Alfonso
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [7] RNFL attenuation coefficients for normal and glaucomatous eyes from standard peripapillary SD-OCT circle scans
    Thepass, Gijs
    de Boer, Johannes F.
    Lemij, Hans G.
    Vermeer, Koenraad Arndt
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [8] Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma
    Shoji, Takuhei
    Nagaoka, Yui
    Sato, Hiroki
    Chihara, Etsuo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1843 - 1849
  • [9] Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma
    Takuhei Shoji
    Yui Nagaoka
    Hiroki Sato
    Etsuo Chihara
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1843 - 1849
  • [10] Evaluation of CANON SD HS 100 OCT : Reproducibility of macular ganglion cell complex (GCC) thickness measurement in normal, hypertensive and glaucomatous eyes
    Rosenberg, R.
    Marill, A. F.
    Fenolland, J. R.
    El Chehab, H.
    Delbarre, M.
    Marechal, M.
    Mouinga, A.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2014, 92