The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes

被引:51
|
作者
Arintawati, Paramastri [1 ]
Sone, Takashi [1 ]
Akita, Tomoyuki [2 ]
Tanaka, Junko [2 ]
Kiuchi, Yoshiaki [1 ]
机构
[1] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Dept Epidemiol Infect Dis Control & Prevent, Grad Sch Biomed Sci, Hiroshima 7348551, Japan
关键词
GCC; RNFL; preperimetric-perimetric glaucoma; OPTICAL COHERENCE TOMOGRAPHY; RETINAL NERVE-FIBER; LAYER THICKNESS; MACULAR VOLUME; VISUAL-FIELD; DOMAIN;
D O I
10.1097/IJG.0b013e318259b2e1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To determine whether the thicknesses of the different parameters of the ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer can be used to differentiate eyes with glaucoma from normal eyes.Methods:Two hundred sixty-one eyes, including 68 normal eyes and 32 preperimetric glaucoma, 81 early glaucoma, and 80 advanced glaucoma were analyzed in the present study. The thicknesses of the GCC and retinal nerve fiber layer were measured using RTVue spectral-domain optical coherence tomographic (SD-OCT) images. The area under the receiver operating characteristic (AUROC) curve and sensitivities at fixed specificities were calculated for each parameter. A logistic regression analysis was used to determine the risk factors for glaucoma.Results:The 2 largest AUROC curves for all glaucoma stages were those for the GCC parameters. The global loss volume (GLV) was always one of the 2 highest values of the AUROC curve. The GLV also had the highest sensitivity at a fixed specificity to identify glaucoma at early and advanced stage. The focal loss volume (FLV) had the largest AUROC curve value and the highest sensitivity at a fixed specificity for advanced glaucoma. The logistic regression analysis showed that the GLV was one of the factors that predicted preperimetric glaucoma [odds ratio (OR)=1.74] and early glaucoma (OR=1.22), whereas the FLV was useful for detecting advanced glaucoma (OR=2.32).Conclusions:The SD-OCT-derived macular GCC parameters can be used to detect preperimetric and perimetric glaucoma. The new GCC parameters, GLV and FLV, performed well in discriminating glaucomatous eyes from normal eyes.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [31] Automatic Retinal Minimum Distance Band (MDB) Computation from SD-OCT Images
    Hussain, Md Akter
    Bhuiyan, Alauddin
    Ramamohanarao, Kotagiri
    2015 INTERNATIONAL CONFERENCE ON DIGITAL IMAGE COMPUTING: TECHNIQUES AND APPLICATIONS (DICTA), 2015, : 190 - 197
  • [32] Support Vector Machine Based IS/OS Disruption Detection from SD-OCT images
    Wang, Liyun
    Zhu, Weifang
    Liao, Jianping
    Xiang, Dehui
    Jin, Chao
    Chen, Haoyu
    Chen, Xinjian
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [33] Reproducibilty of Vessel Density and FAZ Parameters as Measured by Solix SD-OCT AngioAnalytics in Normal, Glaucoma and Retina Eyes
    Wolfson, Yulia
    Lighthizer, Nathan
    Miller, Jeff
    Whittel, Neal
    Naismith, Peter
    Jang, Ben K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [34] Automated Drusen Segmentation and Quantification from SD-OCT Images to Predict AMD Progression
    de Sisternes, Luis
    Leng, Theodore
    Chen, Qiang
    Ma, Jeffrey
    Mahendra, Vibha
    Rubin, Daniel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [35] Weakly supervised individual ganglion cell segmentation from adaptive optics OCT images for glaucomatous damage assessment
    Soltanian-Zadeh, Somayyeh
    Kurokawa, Kazuhiro
    Liu, Zhuolin
    Zhang, Furu
    Saeedi, Osamah
    Hammer, Daniel X.
    Miller, Donald T.
    Farsiu, Sina
    OPTICA, 2021, 8 (05): : 642 - 651
  • [36] Diagnostic Accuracy of Macular Ganglion Cell Layer Thickness Measured by Spectralis SD OCT versus Retinal Nerve Fibre Layer thickness in Discriminating Normal from Glaucomatous eyes
    Elias, Anna
    Anantharaman, Giridhar
    Janardhanan, Saikumar Seshadri
    Nair, Abhilash
    Anup, Manju
    Jacob, Sara
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [37] Deep Learning Approaches Can Detect Glaucomatous Functional Loss better than standard SD-OCT Retinal Nerve Fiber Layer Thickness
    Christopher, Mark
    Belghith, Akram
    Bowd, Christopher
    Goldbaum, Michael Henry
    Weinreb, Robert N.
    Zangwill, Linda M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [38] Effect of Axial Length on the Quality of ONH Scans Acquired from SS-OCT and SD-OCT in Highly Myopic Eyes
    Loh, Isabella Qinxin
    Chong, Rachel
    Dan, Yee Shan
    Wong, Qiu Ying
    Yu, Jason Daryle G.
    Chua, Chloe S. Q.
    Wong, Chee Wai
    Hoang, Quan V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [39] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using the Eye Tracker and the Retest Function of Spectralis SD-OCT in Glaucomatous and Healthy Control Eyes
    Langenegger, Stefan J.
    Funk, Jens
    Toeteberg-Harms, Marc
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (06) : 3338 - 3344
  • [40] The Analysis of Peripapillary RNFL, Macula and Macular Ganglion Cell Layer Thickness in Patients with Monocular Amblyopia Using SD-OCT
    Park, Ji Man
    Choi, Young Je
    Kim, Dae Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (01): : 98 - 105