Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [41] A Comparison of Two Automated Tests of Refractive Error
    Drover, James R.
    Mayo, Deanne
    Bautista, Dorothy
    Bramwell, Lori
    Kielly, Nadine
    Caldwell, Sarah
    Cornick, Shelley
    Davis, Megan
    Pollard, Megan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [42] The influence of variations in ocular biometric and optical parameters on differences in refractive error
    Farzanfar, Arezoo
    Lockett-Ruiz, Veronica
    Navarro, Rafael
    Koppen, Carina
    Rozema, Jos J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (05) : 1000 - 1009
  • [43] Automated geographic atrophy segmentation for SD-OCT images based on two-stage learning model
    Xu, Rongbin
    Niu, Sijie
    Chen, Qiang
    Ji, Zexuan
    Rubin, Daniel
    Chen, Yuehui
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 105 : 102 - 111
  • [44] Comparison of a handheld versus a flexible arm mounted SD-OCT for morphological evaluation of the retina in infants and toddlers
    Lorenz, Birgit
    Holve, Kerstin
    Knobloch, Robert
    Stieger, Knut
    Bowl, Wadim
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [45] Circularity Comparison of the Clinical Optic Disc and Automatically Segmented Neural Canal Opening in SD-OCT Images
    Hu, Z.
    Abramoff, M. A.
    Kwon, Y. H.
    Lee, K.
    Garvin, M. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Effect of refractive errors/axial length on peripapillary retinal nerve fibre layer thickness (RNFL) measured by Topcon SD-OCT
    Kausar, Ayisha
    Akhtar, Nadia
    Afzal, Farooq
    Ali, Khalid
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (07) : 1054 - 1059
  • [47] Structure Function Relationship: ganglion cell complex assessment by two SD-OCT and standard automated perimetry
    El Chehab, Hussam
    Delbarre, Maxime
    Messaoudi, Redouane
    Fenolland, Jean-Remi
    Marie, Marechal
    Francoz, Marlene
    Giraud, Jean-Marie
    May, Frank
    Renard, Jean-Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [48] Reproducibilty of Vessel Density and FAZ Parameters as Measured by Solix SD-OCT AngioAnalytics in Normal, Glaucoma and Retina Eyes
    Wolfson, Yulia
    Lighthizer, Nathan
    Miller, Jeff
    Whittel, Neal
    Naismith, Peter
    Jang, Ben K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [49] SD-OCT peripapillary nerve fibre layer and ganglion cell complex parameters in glaucoma: principal component analysis
    Pazos, Marta
    Biarnes, Marc
    Blasco-Alberto, Andres
    Dyrda, Agnieszka
    Angel Luque-Fernandez, Miguel
    Gomez, Alicia
    Mora, Clara
    Milla, Elena
    Jesus Muniesa, Ma
    Anton, Alfonso
    Tinguaro Diaz-Aleman, Valentin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (04) : 496 - 501
  • [50] Correction of the Retinal Angle in SD-OCT of Glaucomatous Eyes Provides Better Reproducibility of Optic Nerve Head Parameters
    Lee, Kyungmoo
    Kwon, Young
    Abramo, Michael
    Garvin, Mona
    Sonka, Milan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)