Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [21] Comparison of macular thickness analysis between a clinical SD-OCT and a low-cost OCT system
    Bello, Simon
    Bagherinia, Homayoun
    Leahy, Conor
    Shagam, Taylor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [22] Ganglion cell complex measurement and glaucoma diagnosis using two SD-OCT
    Francoz, M.
    El Chehab, H.
    Fenolland, J. R.
    Delbarre, M.
    Marechal, M.
    Ouanezar, S.
    Giraud, J. M.
    May, F.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [23] Morphological parameters and their prognostic value in SD-OCT in patients with center involving retinal detachment
    Rechl, Philip
    Klaas, Julian
    Feucht, Nikolaus
    Lohmann, Chris
    Maier, Mathias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [24] Macular and papillary morphometric evaluation with SD-OCT in children affected by mild-severe refractive errors
    Arpa, C.
    Bianchi, P. E.
    Barilla, D.
    Bertone, C.
    Milano, G.
    Manzoni, F.
    Plaitano, C.
    Periti, F.
    Verticchio, A.
    Tinelli, C.
    Guagliano, R.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 6 - 7
  • [25] Longitudinal fundus and retinal studies with SD-OCT: a comparison of five mouse inbred strains
    Puk, Oliver
    de Angelis, Martin Hrabe
    Graw, Jochen
    MAMMALIAN GENOME, 2013, 24 (5-6) : 198 - 205
  • [26] Comparison of FAF and SD-OCT Geographic Atrophy Lesion Area and Growth Rate Measurements
    Luu, Jennifer Yen
    De Silva, Tharindu
    Gale, Sara
    Standish, Kristopher
    Houwing, Saskia
    Pepio, Anthony
    Chao, Daniel
    Garg, Seema
    McLaughlin, Lucas
    Singh, Rishi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [27] Longitudinal fundus and retinal studies with SD-OCT: a comparison of five mouse inbred strains
    Oliver Puk
    Martin Hrabĕ de Angelis
    Jochen Graw
    Mammalian Genome, 2013, 24 : 198 - 205
  • [28] Comparison Of Vitreous Humor Characteristics Of Children And Adults With Enhanced Vitreous Imaging SD-OCT
    Soberon, Vidal
    Velez-Montoya, Raul
    Garcia-Aguirre, Gerardo
    Wheelock, Lorena
    Morales-Canton, Virgilio
    Quiroz-Mercado, Hugo
    Salcedo, Guillermo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Vasileia Chatzistergiou
    Argyrios Tzamalis
    Asterios Diafas
    Eirini Oustoglou
    Asimina Mataftsi
    Ioannis Tsinopoulos
    Nikolaos Ziakas
    International Ophthalmology, 2023, 43 : 3139 - 3148
  • [30] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Chatzistergiou, Vasileia
    Tzamalis, Argyrios
    Diafas, Asterios
    Oustoglou, Eirini
    Mataftsi, Asimina
    Tsinopoulos, Ioannis
    Ziakas, Nikolaos
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (09) : 3139 - 3148