Advanced dose calculation algorithm in superficial brachytherapy - the impact of tissue inhomogeneity on treatment plan dosimetry

被引:3
|
作者
Szlag, Marta [1 ]
Kellas-Sleczko, Sylwia [2 ]
Wojcieszek, Piotr [2 ]
Stankiewicz, Magdalena [2 ]
Cholewka, Agnieszka [1 ]
Pruefer, Agnieszka [1 ]
Krzysztofiak, Tomasz [2 ]
Lelek, Piotr [2 ]
Stapor-Fudzinska, Malgorzata [1 ]
Slosarek, Krzysztof [1 ]
机构
[1] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Treatment Planning Dept, Wybrzeze Armii Krajowej 15, PL-44102 Gliwice, Poland
[2] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Brachytherapy Dept, Gliwice, Poland
关键词
skin brachytherapy; moulds; TG-186; model-based dose-calculation algorithms; TG-43; RECOMMENDATIONS;
D O I
10.5114/jcb.2021.106541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Given tissue inhomogeneity and lack of backscatter media, superficial brachytherapy necessitates more accurate dosimetry than TG-43 formalism. However, the introduction of modern model-based dose calculation algorithms into clinical practice should be carefully evaluated. The aim of this work was to compare dose distributions calculated with TG-43 and advanced collapsed cone engine (ACE) algorithms for individual multi-catheter moulds, and investigate the impact of target size and the lack of bolus to differences between plans. Material and methods: Eleven treatment plans for individual mould multi-catheter high-dose-rate brachytherapy (IMM HDR) were selected for retrospective analysis. All treatment plans were initially calculated with TG-43 formula and re-calculated using ACE algorithm. Plan re-calculation with ACE was repeated for each plan in order to assess the impact of bolus. To evaluate differences between TG-43 and ACE dose distributions, dose-volume histogram (DVH) parameters for each ROI were compared. D-max (maximal point dose), D-0.1cc, and D-2cc were calculated for each risk's organ (OARs) and for external contour. For clinical target volume (CTV), D-98, D-90, D-50, CTV coverage (CTV-V-100), and dose delivered to reference point were compared between the plans. Results: A significantly lower values (p < 0.05) of CTV parameters were observed for treatment plans calculated with ACE algorithm comparing to TG-43. Further analysis showed that differences between CTV-V-100 for ACE and TG-43 plans depended on CTV volume. Dosimetric parameters for OARs were significantly lower in ACE plans than those of TG-43. Only D-2cc for external and D-0.1cc for both eye lenses in ACE plans were insignificantly different comparing to TG-43 plans. Conclusions: Results show that differences between dosimetric parameters are statistically significant. However, their clinical relevance is still undetermined. Careful re-evaluation of the clinical results based on long-term research on TG-43 is necessary to safely introduce modern algorithms to clinical practice.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] The impact of the bladder volume on the dose to organs at risk dosimetry of vaginal vault brachytherapy
    Hadhemi, Ayadi
    Hajer, Jaffel
    Samia, Ben Hssine
    Takoua, Ben Dhif
    Radhouane, Braiki
    Wiem, Abid
    Manel, Arfaoui
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2024, 34 (SUPPL_1) : A195 - A195
  • [32] Accuracy of a Commercially Available Dose Calculation Algorithm for Small Field Dosimetry
    Stathakis, S.
    Esquivel, C.
    Gutierrez, A.
    Mihailidis, D.
    Buckey, C.
    Myers, P.
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] Validation of a Simple Portal Dose Calculation Model for Plan QA and In-Vivo Dosimetry
    Lu, W.
    Chen, M.
    Mo, X.
    Parnell, D.
    Olivera, G.
    Galmarini, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [34] Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source
    Ravikumar, Barlanka
    Lakshminarayana, S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 27 - 31
  • [35] Impact of Lung Tissue in Intraoperative 125I and 103Pd Mesh Brachytherapy Dose Calculation
    Zhang, H.
    Das, I. J.
    Johnstone, P. A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S900 - S900
  • [36] Impact of dose calculation algorithm on radiation therapy
    Chen, Wen-Zhou
    Xiao, Ying
    Li, Jun
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (11): : 874 - 880
  • [37] Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)
    Placidi, Elisa
    Fionda, Bruno
    Rosa, Enrico
    Lancellotta, Valentina
    Napolitano, Antonio
    De Angeli, Martina
    Pastore, Francesco
    Gambacorta, Maria Antonietta
    Indovina, Luca
    Tagliaferri, Luca
    De Spirito, Marco
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (06) : 448 - 452
  • [38] Dosimetric Impact of Air Pockets in the Vaginal Cuff Brachytherapy Using Model-based Dose Calculation Algorithm
    Puriparthi, Lakshmi Venkataramana
    Talluri, Anil Kumar
    Akkineni, Naga Prasanthi
    Bajwa, Harjot Kaur
    Tumu, Venkatappa Rao
    Sresty, N. V. N. Madhusudhana
    Alluri, Krishnam Raju
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 373 - 377
  • [39] Dosimetry and treatment planning in high dose rate Cf-252 brachytherapy
    Denisenko, ON
    Ivanov, VN
    Kozlov, VA
    Sidorchenkov, VO
    Omarov, AA
    Chernichenko, IM
    Chekhonadsky, VN
    CALIFORNIUM-252: ISOTOPE FOR 21ST CENTURY RADIOTHERAPY, 1997, 29 : 221 - 231
  • [40] Impact of inhomogeneity corrected dose calculation on dosimetric quality parameters in gynaecological cases
    Hofbauer, J.
    Nesvacil, N.
    Sturdza, A.
    Poetter, R.
    Kirisits, C. '
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S101 - S101