Advanced dose calculation algorithm in superficial brachytherapy - the impact of tissue inhomogeneity on treatment plan dosimetry

被引:3
|
作者
Szlag, Marta [1 ]
Kellas-Sleczko, Sylwia [2 ]
Wojcieszek, Piotr [2 ]
Stankiewicz, Magdalena [2 ]
Cholewka, Agnieszka [1 ]
Pruefer, Agnieszka [1 ]
Krzysztofiak, Tomasz [2 ]
Lelek, Piotr [2 ]
Stapor-Fudzinska, Malgorzata [1 ]
Slosarek, Krzysztof [1 ]
机构
[1] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Treatment Planning Dept, Wybrzeze Armii Krajowej 15, PL-44102 Gliwice, Poland
[2] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Brachytherapy Dept, Gliwice, Poland
关键词
skin brachytherapy; moulds; TG-186; model-based dose-calculation algorithms; TG-43; RECOMMENDATIONS;
D O I
10.5114/jcb.2021.106541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Given tissue inhomogeneity and lack of backscatter media, superficial brachytherapy necessitates more accurate dosimetry than TG-43 formalism. However, the introduction of modern model-based dose calculation algorithms into clinical practice should be carefully evaluated. The aim of this work was to compare dose distributions calculated with TG-43 and advanced collapsed cone engine (ACE) algorithms for individual multi-catheter moulds, and investigate the impact of target size and the lack of bolus to differences between plans. Material and methods: Eleven treatment plans for individual mould multi-catheter high-dose-rate brachytherapy (IMM HDR) were selected for retrospective analysis. All treatment plans were initially calculated with TG-43 formula and re-calculated using ACE algorithm. Plan re-calculation with ACE was repeated for each plan in order to assess the impact of bolus. To evaluate differences between TG-43 and ACE dose distributions, dose-volume histogram (DVH) parameters for each ROI were compared. D-max (maximal point dose), D-0.1cc, and D-2cc were calculated for each risk's organ (OARs) and for external contour. For clinical target volume (CTV), D-98, D-90, D-50, CTV coverage (CTV-V-100), and dose delivered to reference point were compared between the plans. Results: A significantly lower values (p < 0.05) of CTV parameters were observed for treatment plans calculated with ACE algorithm comparing to TG-43. Further analysis showed that differences between CTV-V-100 for ACE and TG-43 plans depended on CTV volume. Dosimetric parameters for OARs were significantly lower in ACE plans than those of TG-43. Only D-2cc for external and D-0.1cc for both eye lenses in ACE plans were insignificantly different comparing to TG-43 plans. Conclusions: Results show that differences between dosimetric parameters are statistically significant. However, their clinical relevance is still undetermined. Careful re-evaluation of the clinical results based on long-term research on TG-43 is necessary to safely introduce modern algorithms to clinical practice.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [21] TREATMENT PLAN OPTIMIZATION USING DIFFERENT METHODS OF DOSE INHOMOGENEITY REGULARIZATION
    Komisopoulos, G.
    Mavroidis, P.
    Papanikolaou, N.
    Lind, B.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S424 - S424
  • [22] The Impact of Dose Calculation Algorithm for SBRT Lung Cancer Radiotherapy Treatment
    Mostafa A.A.
    Hussein A.E.-A.E.
    Galal M.M.
    El-Shahat K.M.
    Iranian Journal of Medical Physics, 2022, 19 (05) : 290 - 295
  • [23] Thermoluminescence dosimetry dose verification of a high dose rate brachytherapy treatment planning in phantom
    Sakulsingharoj, S.
    Tangboonduangjit, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S328 - S328
  • [24] Dose model-based dose calculation have impact to dose distribution in brachytherapy?
    Frohlich, Georgina
    Jolesz, Zsofia
    Vizkeleti, Julia
    Bajcsay, Andras
    Major, Tibor
    Takacsi, Zoltan Nagy
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S336 - S338
  • [25] A plan intercomparison study for advanced algorithms for photon dose calculation
    Fogliata, A.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Cozzi, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 178 - 178
  • [26] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Duque, Anna Sophie
    Corradini, Stefanie
    Kamp, Florian
    Seidensticker, Max
    Streitparth, Florian
    Kurz, Christopher
    Walter, Franziska
    Parodi, Katia
    Verhaegen, Frank
    Ricke, Jens
    Belka, Claus
    Fonseca, Gabriel Paiva
    Landry, Guillaume
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [27] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Anna Sophie Duque
    Stefanie Corradini
    Florian Kamp
    Max Seidensticker
    Florian Streitparth
    Christopher Kurz
    Franziska Walter
    Katia Parodi
    Frank Verhaegen
    Jens Ricke
    Claus Belka
    Gabriel Paiva Fonseca
    Guillaume Landry
    Radiation Oncology, 15
  • [28] Impact of Model Based Dose Calculation Algorithm for Ir-192 Intracavitary Brachytherapy with Shielded Applicator
    Mikell, J.
    Klopp, A.
    Price, M.
    Mourtada, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3802 - 3802
  • [29] A Sensitivity Study of Tissue Characterization for Brachytherapy Monte Carlo Dose Calculation
    Bedwani, S.
    Carrier, J.
    Bouchard, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Independent calculation of dose for a helical TomoTherapy treatment plan
    Gibbons, J.
    Smith, K.
    Cheek, D.
    Rosen, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2112 - 2112