Advanced dose calculation algorithm in superficial brachytherapy - the impact of tissue inhomogeneity on treatment plan dosimetry

被引:3
|
作者
Szlag, Marta [1 ]
Kellas-Sleczko, Sylwia [2 ]
Wojcieszek, Piotr [2 ]
Stankiewicz, Magdalena [2 ]
Cholewka, Agnieszka [1 ]
Pruefer, Agnieszka [1 ]
Krzysztofiak, Tomasz [2 ]
Lelek, Piotr [2 ]
Stapor-Fudzinska, Malgorzata [1 ]
Slosarek, Krzysztof [1 ]
机构
[1] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Treatment Planning Dept, Wybrzeze Armii Krajowej 15, PL-44102 Gliwice, Poland
[2] Maria Sklodowska Curie Natl Res Inst Oncol Gliwic, Brachytherapy Dept, Gliwice, Poland
关键词
skin brachytherapy; moulds; TG-186; model-based dose-calculation algorithms; TG-43; RECOMMENDATIONS;
D O I
10.5114/jcb.2021.106541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Given tissue inhomogeneity and lack of backscatter media, superficial brachytherapy necessitates more accurate dosimetry than TG-43 formalism. However, the introduction of modern model-based dose calculation algorithms into clinical practice should be carefully evaluated. The aim of this work was to compare dose distributions calculated with TG-43 and advanced collapsed cone engine (ACE) algorithms for individual multi-catheter moulds, and investigate the impact of target size and the lack of bolus to differences between plans. Material and methods: Eleven treatment plans for individual mould multi-catheter high-dose-rate brachytherapy (IMM HDR) were selected for retrospective analysis. All treatment plans were initially calculated with TG-43 formula and re-calculated using ACE algorithm. Plan re-calculation with ACE was repeated for each plan in order to assess the impact of bolus. To evaluate differences between TG-43 and ACE dose distributions, dose-volume histogram (DVH) parameters for each ROI were compared. D-max (maximal point dose), D-0.1cc, and D-2cc were calculated for each risk's organ (OARs) and for external contour. For clinical target volume (CTV), D-98, D-90, D-50, CTV coverage (CTV-V-100), and dose delivered to reference point were compared between the plans. Results: A significantly lower values (p < 0.05) of CTV parameters were observed for treatment plans calculated with ACE algorithm comparing to TG-43. Further analysis showed that differences between CTV-V-100 for ACE and TG-43 plans depended on CTV volume. Dosimetric parameters for OARs were significantly lower in ACE plans than those of TG-43. Only D-2cc for external and D-0.1cc for both eye lenses in ACE plans were insignificantly different comparing to TG-43 plans. Conclusions: Results show that differences between dosimetric parameters are statistically significant. However, their clinical relevance is still undetermined. Careful re-evaluation of the clinical results based on long-term research on TG-43 is necessary to safely introduce modern algorithms to clinical practice.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] The Impact of Dose Calculation Algorithm and Hounsfield Units Conversion Tables On Plan Dosimetry for Lung SBRT
    Kuo, L.
    Yorke, E.
    Lim, S.
    Mechalakos, J.
    Rimner, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 398 - 398
  • [2] Vaginal Cylinder HDR Brachytherapy: Effect of Inhomogeneity On Dose Calculation
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [3] Impact of Dose Calculation Algorithm On Airway Dosimetry: Comparison of AAA and Acuros
    Kinkopf, P.
    Modiri, A.
    Yu, K.
    Yan, Y.
    Mohindra, P.
    Timmerman, R.
    Sawant, A.
    Vicente, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [4] On the impact of improved dose calculation accuracy in clinical treatment planning for superficial high-dose-rate brachytherapy of extensive scalp lesions
    Rossi, Giulio
    Peppa, Vasiliki
    Gainey, Mark
    Kollefrath, Michael
    Sprave, Tanja
    Papagiannis, Panagiotis
    Baltas, Dimos
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [5] Recommended dose calculation formalism and consensus dosimetry parameters for intravascular brachytherapy dosimetry
    Nath, R
    Chiu-Tsao, S
    Schaart, D
    Soares, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1744 - 1745
  • [6] Comparison of Dose Distribution by the Difference of Dose Calculation Algorithm for the Same Treatment Plan
    Inoue, K.
    Matsukawa, H.
    Kasai, Y.
    Edamitsu, K.
    Matsumoto, K.
    Takayama, Y.
    Hirose, T.
    Fukunaga, J.
    Shioyama, Y.
    Sasaki, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E726 - E726
  • [7] Model-Based Dose Calculation Algorithms for Brachytherapy Dosimetry
    Enger, Shirin A.
    Vijande, Javier
    Rivard, Mark J.
    SEMINARS IN RADIATION ONCOLOGY, 2020, 30 (01) : 77 - 86
  • [8] Dosimetric Accuracy Analysis of Dose Calculation Algorithms Using Inhomogeneity Phantom for IMRT Treatment Plan
    Lah, J.
    Park, J.
    Suh, T.
    Shin, D.
    Lee, S.
    Yoon, M.
    Park, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Superficial cancer of the esophagus: Radiation therapy, combined treatment and impact of high dose rate brachytherapy
    Maingon, P
    D'Hombres, A
    Truc, G
    Barillot, I
    Michiels, C
    Bedenne, L
    RADIOLOGY, 1998, 209P : 437 - 437
  • [10] A deterministic dose calculation method applied to the Dosimetry of shielded intracavitary brachytherapy applicators
    Mourtada, F
    Wareing, T
    Horton, J
    McGhee, J
    Barnett, D
    Gifford, K
    Failla, G
    Mohan, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1807 - 1808