Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)

被引:5
|
作者
Placidi, Elisa [1 ]
Fionda, Bruno [2 ]
Rosa, Enrico [3 ]
Lancellotta, Valentina [2 ]
Napolitano, Antonio [4 ]
De Angeli, Martina [2 ]
Pastore, Francesco [2 ]
Gambacorta, Maria Antonietta [2 ,5 ]
Indovina, Luca [1 ]
Tagliaferri, Luca [2 ]
De Spirito, Marco [1 ,3 ]
机构
[1] IRCCS, Fdn Policlin Univ Agostino Gemelli, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sci Vita, Rome, Italy
[2] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Radioterapia Oncol, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Fis, Largo Francesco Vito 1, I-00168 Rome, Italy
[4] IRCCS Bambino Gesu Childrens Hosp, Dept Med Phys, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
关键词
brachytherapy; TG-43; interventional radiotherapy; TG-186; non-melanoma skin cancer; NASAL VESTIBULE; RECOMMENDATIONS; TG-43;
D O I
10.5114/jcb.2023.134173
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Brachytherapy (BT, interventional radiotherapy) is a well-established radiotherapy technique capable of delivering high doses to tumors while sparing organs at risk (OARs). Currently, the clinically accepted dose calculation algorithm used is TG-43. In the TG-186 report, new model-based dose calculation algorithms (MBDCA), such as Elekta's advanced collapsed cone engine (ACE), have been introduced, although their clinical application is yet to be fully realized. This study aimed to investigate two aspects of TG-186: firstly, a comparison of dose distributions calculated with TG-43 and TG-186 for skin tumors; and secondly, an exploration of the impact of using a water bolus on the coverage of clinical target volume (CTV) and OARs. Material and methods: Ten treatment plans for high-dose-rate IRT were developed. All plans were initially calculated using the TG-43 algorithm, and were subsequently re-calculated with TG-186. In addition, one of the treatment plans was assessed with both TG-43 and TG-186, using 10 different water bolus thicknesses ranging from 0 to 5 cm. To assess dose variations, the following dose-volume histogram (DVH) parameters were compared: D2cc and D0.01cc Results and conclusions: The average dosimetric results for CTV and OARs, as calculated by both algorithms, revealed statistically significant lower values for TG-186 when compared with TG-43. The presence of a bolus was observed to enhance CTV coverage for the TG-186 algorithm, with a bolus thickness of 2 cm being the point at which ACE calculations matched those of TG-43. This study identified significant differences in dosimetric parameters for skin tumors when comparing the TG-43 and TG-186 algorithms. Moreover, it was demonstrated that the inclusion of a water bolus increased CTV coverage in TG-186 calculations.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [1] Dosimetric impact of a model-based dose calculation algorithm in skin interventional radiotherapy
    Placidi, Elisa
    Fionda, Bruno
    Rosa, Enrico
    Lancellotta, Valentina
    Napolitano, Antonio
    De Angeli, Martina
    Pastore, Francesco
    Gambacorta, Maria Antonietta
    Indovina, Luca
    Tagliaferri, Luca
    De Spirito, Marco
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S378 - S380
  • [2] Dosimetric impact of a model based algorithm for skin cancer interventional radiotherapy
    Placidi, E.
    Napolitano, A.
    Fionda, B.
    Stimato, G.
    Lancellotta, V.
    Teodoli, S.
    Casa, C.
    Greco, F.
    Cornacchione, P.
    Menna, S.
    Meffe, G.
    Gambacorta, M. A.
    Tagliaferri, L.
    Indovina, L.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S187 - S188
  • [3] Dosimetric Impact of Air Pockets in the Vaginal Cuff Brachytherapy Using Model-based Dose Calculation Algorithm
    Puriparthi, Lakshmi Venkataramana
    Talluri, Anil Kumar
    Akkineni, Naga Prasanthi
    Bajwa, Harjot Kaur
    Tumu, Venkatappa Rao
    Sresty, N. V. N. Madhusudhana
    Alluri, Krishnam Raju
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 373 - 377
  • [4] A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy
    Yousif, Yousif A. M.
    Osman, Alexander F., I
    Halato, Mohammed A.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (03) : 871 - 886
  • [5] A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy
    Yousif A. M. Yousif
    Alexander F. I. Osman
    Mohammed A. Halato
    Physical and Engineering Sciences in Medicine, 2021, 44 : 871 - 886
  • [6] Dose model-based dose calculation have impact to dose distribution in brachytherapy?
    Frohlich, Georgina
    Jolesz, Zsofia
    Vizkeleti, Julia
    Bajcsay, Andras
    Major, Tibor
    Takacsi, Zoltan Nagy
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S336 - S338
  • [7] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Duque, Anna Sophie
    Corradini, Stefanie
    Kamp, Florian
    Seidensticker, Max
    Streitparth, Florian
    Kurz, Christopher
    Walter, Franziska
    Parodi, Katia
    Verhaegen, Frank
    Ricke, Jens
    Belka, Claus
    Fonseca, Gabriel Paiva
    Landry, Guillaume
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [8] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Anna Sophie Duque
    Stefanie Corradini
    Florian Kamp
    Max Seidensticker
    Florian Streitparth
    Christopher Kurz
    Franziska Walter
    Katia Parodi
    Frank Verhaegen
    Jens Ricke
    Claus Belka
    Gabriel Paiva Fonseca
    Guillaume Landry
    Radiation Oncology, 15
  • [10] Evaluation of a Model Based Dose Calculation Algorithm for skin interventional radiation therapy
    Rosa, E.
    Breschi, L.
    Fionda, B.
    Lancellotta, V.
    Stimato, G.
    Meffe, G.
    Cornacchione, P.
    Tagliaferri, L.
    Indovina, L.
    Placidi, E.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1778 - S1779