Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)

被引:5
|
作者
Placidi, Elisa [1 ]
Fionda, Bruno [2 ]
Rosa, Enrico [3 ]
Lancellotta, Valentina [2 ]
Napolitano, Antonio [4 ]
De Angeli, Martina [2 ]
Pastore, Francesco [2 ]
Gambacorta, Maria Antonietta [2 ,5 ]
Indovina, Luca [1 ]
Tagliaferri, Luca [2 ]
De Spirito, Marco [1 ,3 ]
机构
[1] IRCCS, Fdn Policlin Univ Agostino Gemelli, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sci Vita, Rome, Italy
[2] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Radioterapia Oncol, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Fis, Largo Francesco Vito 1, I-00168 Rome, Italy
[4] IRCCS Bambino Gesu Childrens Hosp, Dept Med Phys, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
关键词
brachytherapy; TG-43; interventional radiotherapy; TG-186; non-melanoma skin cancer; NASAL VESTIBULE; RECOMMENDATIONS; TG-43;
D O I
10.5114/jcb.2023.134173
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Brachytherapy (BT, interventional radiotherapy) is a well-established radiotherapy technique capable of delivering high doses to tumors while sparing organs at risk (OARs). Currently, the clinically accepted dose calculation algorithm used is TG-43. In the TG-186 report, new model-based dose calculation algorithms (MBDCA), such as Elekta's advanced collapsed cone engine (ACE), have been introduced, although their clinical application is yet to be fully realized. This study aimed to investigate two aspects of TG-186: firstly, a comparison of dose distributions calculated with TG-43 and TG-186 for skin tumors; and secondly, an exploration of the impact of using a water bolus on the coverage of clinical target volume (CTV) and OARs. Material and methods: Ten treatment plans for high-dose-rate IRT were developed. All plans were initially calculated using the TG-43 algorithm, and were subsequently re-calculated with TG-186. In addition, one of the treatment plans was assessed with both TG-43 and TG-186, using 10 different water bolus thicknesses ranging from 0 to 5 cm. To assess dose variations, the following dose-volume histogram (DVH) parameters were compared: D2cc and D0.01cc Results and conclusions: The average dosimetric results for CTV and OARs, as calculated by both algorithms, revealed statistically significant lower values for TG-186 when compared with TG-43. The presence of a bolus was observed to enhance CTV coverage for the TG-186 algorithm, with a bolus thickness of 2 cm being the point at which ACE calculations matched those of TG-43. This study identified significant differences in dosimetric parameters for skin tumors when comparing the TG-43 and TG-186 algorithms. Moreover, it was demonstrated that the inclusion of a water bolus increased CTV coverage in TG-186 calculations.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [21] The Impact of Dose Calculation Algorithm for SBRT Lung Cancer Radiotherapy Treatment
    Mostafa A.A.
    Hussein A.E.-A.E.
    Galal M.M.
    El-Shahat K.M.
    Iranian Journal of Medical Physics, 2022, 19 (05) : 290 - 295
  • [22] Impact of Model Based Dose Calculation Algorithm for Ir-192 Intracavitary Brachytherapy with Shielded Applicator
    Mikell, J.
    Klopp, A.
    Price, M.
    Mourtada, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3802 - 3802
  • [23] Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix
    Jacob, Dayee
    Lamberto, Melissa
    Lawrence, Lana DeSouza
    Mourtada, Firas
    BRACHYTHERAPY, 2017, 16 (03) : 624 - 629
  • [24] Evaluation of a Model-based Dose Calculation Algorithm (Acuros) for Intraosseous High Dose Rate Brachytherapy (HDR) With Intramedullary Nailing for Bone Metastases
    Rezaeian, N. Hassan
    Gannavarapu, B. S.
    Folkert, M. R.
    Timmerman, R. D.
    Hrycushko, B. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E292 - E292
  • [25] Effect of model-based dose-calculation algorithms in high dose rate brachytherapy of cervical carcinoma
    Srivastava, Shraddha
    Venugopal, Ajay Kannathuparambil
    Singh, Moirangthem Nara
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (03) : 300 - 308
  • [26] Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy
    Tedgren, Asa Carlsson
    Carlsson, Gudrun Alm
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08): : 2561 - 2579
  • [27] A Model-Based Dose Calculation Algorithm for Kilovoltage X-Rays
    Pawlowski, J.
    Ding, G.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Generation of 3D Dosimetric Reference Datasets for Commissioning and Validation of 192Ir Brachytherapy Model-Based Dose Calculation Software
    Ma, Y.
    Vijande, J.
    Ballester, F.
    Tedgren, Asa Carlsson
    Granero, D.
    Haworth, A.
    Mourtada, F.
    Fonseca, G.
    Zourari, K.
    Papagiannis, P.
    Rivard, M.
    Siebert, F.
    Sloboda, R.
    Smith, R.
    Thomson, R.
    Verhaegen, F.
    Beaulieu, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3707 - 3707
  • [29] Dosimetric impact of Acuros XB dose calculation algorithm in prostate cancer treatment using RapidArc
    Rana, Suresh
    Rogers, Kevin
    Lee, Terry
    Reed, Daniel
    Biggs, Christopher
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (03) : 430 - 435
  • [30] Commissioning a model-based Dose Calculation Algorithms for Brachytherapy according to the TG-186 Report
    Krause, F.
    Krause, T. -M
    Bohn, S.
    Siebert, F. -A
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S19 - S19