Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)

被引:5
|
作者
Placidi, Elisa [1 ]
Fionda, Bruno [2 ]
Rosa, Enrico [3 ]
Lancellotta, Valentina [2 ]
Napolitano, Antonio [4 ]
De Angeli, Martina [2 ]
Pastore, Francesco [2 ]
Gambacorta, Maria Antonietta [2 ,5 ]
Indovina, Luca [1 ]
Tagliaferri, Luca [2 ]
De Spirito, Marco [1 ,3 ]
机构
[1] IRCCS, Fdn Policlin Univ Agostino Gemelli, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sci Vita, Rome, Italy
[2] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Radioterapia Oncol, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Fis, Largo Francesco Vito 1, I-00168 Rome, Italy
[4] IRCCS Bambino Gesu Childrens Hosp, Dept Med Phys, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
关键词
brachytherapy; TG-43; interventional radiotherapy; TG-186; non-melanoma skin cancer; NASAL VESTIBULE; RECOMMENDATIONS; TG-43;
D O I
10.5114/jcb.2023.134173
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Brachytherapy (BT, interventional radiotherapy) is a well-established radiotherapy technique capable of delivering high doses to tumors while sparing organs at risk (OARs). Currently, the clinically accepted dose calculation algorithm used is TG-43. In the TG-186 report, new model-based dose calculation algorithms (MBDCA), such as Elekta's advanced collapsed cone engine (ACE), have been introduced, although their clinical application is yet to be fully realized. This study aimed to investigate two aspects of TG-186: firstly, a comparison of dose distributions calculated with TG-43 and TG-186 for skin tumors; and secondly, an exploration of the impact of using a water bolus on the coverage of clinical target volume (CTV) and OARs. Material and methods: Ten treatment plans for high-dose-rate IRT were developed. All plans were initially calculated using the TG-43 algorithm, and were subsequently re-calculated with TG-186. In addition, one of the treatment plans was assessed with both TG-43 and TG-186, using 10 different water bolus thicknesses ranging from 0 to 5 cm. To assess dose variations, the following dose-volume histogram (DVH) parameters were compared: D2cc and D0.01cc Results and conclusions: The average dosimetric results for CTV and OARs, as calculated by both algorithms, revealed statistically significant lower values for TG-186 when compared with TG-43. The presence of a bolus was observed to enhance CTV coverage for the TG-186 algorithm, with a bolus thickness of 2 cm being the point at which ACE calculations matched those of TG-43. This study identified significant differences in dosimetric parameters for skin tumors when comparing the TG-43 and TG-186 algorithms. Moreover, it was demonstrated that the inclusion of a water bolus increased CTV coverage in TG-186 calculations.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [41] Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?
    Karius, Andre
    Shariff, Maya
    Schaller, Sabrina
    Lotter, Michael
    Strnad, Vratislav
    Lackner, Niklas
    Fietkau, Rainer
    Bert, Christoph
    Merten, Ricarda
    Schweizer, Claudia
    STRAHLENTHERAPIE UND ONKOLOGIE, 2025, 201 (01) : 57 - 70
  • [42] Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer
    Aebersold, DM
    Isaak, B
    Thalmann, G
    Behrensmeier, F
    Kolotas, C
    Kranzbühler, H
    Mini, R
    Greiner, RH
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 (06) : 351 - 357
  • [43] On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning
    Pappas, Eleftherios P.
    Zoros, Emmanouil
    Moutsatsos, Argyris
    Peppa, Vasiliki
    Zourari, Kyveli
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 4160 - 4182
  • [44] Generation of 3D Dosimetric Reference Datasets Using Model-Based Dose Calculations for COMS Eye Plaque Brachytherapy
    Fletcher, E.
    Ballester, F.
    Beaulieu, L.
    Ma, Y.
    Morrison, H.
    Rivard, M.
    Sloboda, R.
    Vijande, J.
    Thomson, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [45] Generation of 3D Dosimetric Reference Datasets Using Model-Based Dose Calculations for COMS Eye Plaque Brachytherapy
    Fletcher, E.
    Ballester, F.
    Beaulieu, L.
    Ma, Y.
    Morrison, H.
    Rivard, M. J.
    Sloboda, R.
    Vijande, J.
    Thomson, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E788 - E788
  • [46] Development of Multiple Dwell Techniques in Horizontally-Oriented Leipzig-Style Applicators for Surface Brachytherapy Guided by a Model-Based Dose Calculation Algorithm
    Draeger, E.
    Pinkham, D.
    Chen, Z.
    Tien, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E745 - E745
  • [47] The role of personalized Interventional Radiotherapy (brachytherapy) in the management of older patients with non-melanoma skin cancer
    Lancellotta, Valentina
    Kovacs, Gyoergy
    Tagliaferri, Luca
    Perrucci, Elisabetta
    Rembielak, Agata
    Stingeni, Luca
    Tramontana, Marta
    Hansel, Katharina
    Colloca, Giuseppe
    Saldi, Simonetta
    Valentini, Vincenzo
    Aristei, Cynthia
    JOURNAL OF GERIATRIC ONCOLOGY, 2019, 10 (03) : 514 - 517
  • [48] Palliative treatment with high-dose-rate endobronchial interventional radiotherapy (Brachytherapy) for lung cancer patients
    Soror, Tamer
    Kovacs, Gyorgy
    Wecker, Sacha
    Ismail, Mahmoud
    Badakhshi, Harun
    BRACHYTHERAPY, 2021, 20 (06) : 1269 - 1275
  • [49] Validation of a Commercial Model-Based Collapsed Cone Dose Algorithm for High Dose-Rate Gynecological Brachytherapy Treatment Planning
    Price, M. J.
    Fontenot, J. D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] Model-based dose calculations for 125I lung brachytherapy
    Sutherland, J. G. H.
    Furutani, K. M.
    Garces, Y. I.
    Thomson, R. M.
    MEDICAL PHYSICS, 2012, 39 (07) : 4365 - 4377