Comparative Analysis of Cutting Efficiency and Surface Maintenance Between Different Types of Implant Drills: An In Vitro Study

被引:4
|
作者
Hochscheidt, Celso Joao [1 ,2 ]
Shimizu, Roberto Hideo [3 ,4 ,5 ]
Andrighetto, Augusto Ricardo [6 ,7 ,8 ]
Pierezan, Rodrigo [9 ,10 ]
Thome, Geninho [11 ,12 ,13 ]
Salatti, Rafael [14 ]
机构
[1] ILAPEO, Implant Dent, Curitiba, PR, Brazil
[2] Clin Top Odontol, Rua Coronel Bittencourt 618, BR-84010290 Ponta Grossa, PR, Brazil
[3] Univ Estadual Paulista UNESP, Orthodont, Araraquara, SP, Brazil
[4] Masters Program Orthodont, Curitiba, PR, Brazil
[5] ILAPEO, Dept Orthodont, Curitiba, PR, Brazil
[6] Univ Sao Paulo, Orthodont, Sao Paulo, SP, Brazil
[7] ILAPEO, Grad Program Orthodont, Dept Orthodont, Curitiba, PR, Brazil
[8] ILAPEO, Grad Program Implant Dent, Dept Orthodont, Curitiba, PR, Brazil
[9] Pontificia Univ Catolica Parana PUCPR, Dept Mechatron Control & Automat, Prod & Syst Engn, Curitiba, PR, Brazil
[10] Soc Ensino Tecn Ensitec, Curitiba, PR, Brazil
[11] Res Ctr Sao Leopoldo Mand Dent, Dent Surg, Curitiba, PR, Brazil
[12] ILAPEO, Curitiba, PR, Brazil
[13] Neodent Osseointegrated Implants, Curitiba, PR, Brazil
[14] Noodent Osscointegrated Implants, Dept Res Dev & Innovat, Curitiba, PR, Brazil
关键词
osteotomy; performance testing; dental implants; tribology; BONE CELL VIABILITY; HEAT-PRODUCTION; CERAMIC DRILLS; CORTICAL BONE; WEAR; OSTEOTOMY; SITE; STERILIZATION; DEFORMATION; TEMPERATURE;
D O I
10.1097/ID.0000000000000645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study evaluated cutting efficiency (CE) and linear wear of dental implant drills after 450 standardized osteotomies on bovine ribs. Diamond-like carbon-coated steel drills (SG), acid-treated steel drills (EG), and ceramic drills (ZG) were divided into 6 subgroups according to the number of uses. Materials and Methods: A robot-controlled program performed systematic instrumentation, timing, axial loading, and managed feed rate. CE was recorded in a polyurethane resin blank and end wear (VBBmax) was analyzed under stereo microscopy. Results: After osteotomies in beef ribs, CE for the phi 2.0-mm drill decreased 10.2% in SG and 10.9% in ZG; for the phi 3.0-mm drill, CE decreased 30.6% in SG, 8.5% in ZG, and improved in EG. The greatest wear occurred in O2.0-mm drills; ZG drills (phi 3.0 mm) exhibited only edge frittering, as confirmed on scanning electron microscopy. Conclusion: After 50 exposures to mechanical loads, steel and ceramic drills lost CE. Whereas cutting and thermal performance improved in experimental drills, the phi 2.0-mm drill exhibited the most signs of wear proportional to use. These findings suggest that, with the methodology employed, the life of these drills exceeds 50 osteotomies.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 50 条
  • [1] Comparative Analysis of the Chemical Composition and Microstructure Conformation Between Different Dental Implant Bone Drills
    Marenzi, Gaetano
    Sammartino, Jose Camilla
    Scherillo, Fabio
    Rengo, Carlo
    De Rosa, Alfredo
    Graziano, Vincenzo
    Spagnuolo, Gianrico
    MATERIALS, 2019, 12 (11) : 1866
  • [2] Comparative analysis of different implant impression techniques: An In vitro study
    Agnihotri, Radhika R.
    Naik, Saloni
    Vaishnav, Kalpesh
    Shah, Dipti S.
    Joshi, Ravi
    Bhatt, Miloni
    ADVANCES IN HUMAN BIOLOGY, 2023, 13 (05) : 44 - 51
  • [3] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [4] Maintenance of implants: An in vitro study of titanium implant surface modifications subsequent to the application of different prophylaxis procedures
    Matarasso, S
    Quaremba, G
    Coraggio, F
    Vaia, E
    Cafiero, C
    Lang, NP
    CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (01) : 64 - 72
  • [5] Experimental comparative study between two types of mechanism used in grassland drills transmission
    Manea, D.
    Voicu, Gh.
    Paraschiv, G.
    Marin, E.
    INMATEH - Agricultural Engineering, 2015, 47 (03): : 5 - 12
  • [6] EXPERIMENTAL ANALYSIS OF THE EFFECT OF CUTTING CONDITIONS ON THE INITIAL PENETRATION IN DRILLING: A COMPARATIVE STUDY BETWEEN CONVENTIONAL AND SPLIT CHISEL DRILLS
    Park, Sungwoo
    Abu-Mahfouz, Issam
    Banerjee, Amit
    PROCEEDINGS OF THE ASME INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, VOL 2, 2009, : 481 - 488
  • [7] Evaluation of the impact of different surface treatments on implant surface: An In Vitro study
    Jalaluddin, Mohammad
    Subramanian, Deepa
    Mathew, Joel
    Mailankote, Shilpa
    Almuraikhi, Turki
    Daghriri, Alhussain
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : 1132 - 1135
  • [8] The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study
    Giffi, Roberto
    Pietropaoli, Davide
    Mancini, Leonardo
    Tarallo, Francesco
    Sahrmann, Philipp
    Marchetti, Enrico
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2023, 53 (04): : 295 - 305
  • [9] Microscopic Analysis and Evaluation of Thermal Elevation and Wear of Drills for Implant Site Preparation: An In Vitro Study
    Meme, Lucia
    Bambini, Fabrizio
    Pizzolante, Tommaso
    Principi, Martina
    Sampalmieri, Francesco
    Mummolo, Stefano
    MATERIALS, 2024, 17 (22)
  • [10] Comparison between four different implant surface debridement methods: an in-vitro experimental study
    Mensi, Magda
    Viviani, Lorenzo
    Agosti, Raffaele
    Scotti, Eleonora
    Garzetti, Gianluca
    Calza, Stefano
    MINERVA STOMATOLOGICA, 2020, 69 (05): : 286 - 294