Comparative Analysis of Cutting Efficiency and Surface Maintenance Between Different Types of Implant Drills: An In Vitro Study

被引:4
|
作者
Hochscheidt, Celso Joao [1 ,2 ]
Shimizu, Roberto Hideo [3 ,4 ,5 ]
Andrighetto, Augusto Ricardo [6 ,7 ,8 ]
Pierezan, Rodrigo [9 ,10 ]
Thome, Geninho [11 ,12 ,13 ]
Salatti, Rafael [14 ]
机构
[1] ILAPEO, Implant Dent, Curitiba, PR, Brazil
[2] Clin Top Odontol, Rua Coronel Bittencourt 618, BR-84010290 Ponta Grossa, PR, Brazil
[3] Univ Estadual Paulista UNESP, Orthodont, Araraquara, SP, Brazil
[4] Masters Program Orthodont, Curitiba, PR, Brazil
[5] ILAPEO, Dept Orthodont, Curitiba, PR, Brazil
[6] Univ Sao Paulo, Orthodont, Sao Paulo, SP, Brazil
[7] ILAPEO, Grad Program Orthodont, Dept Orthodont, Curitiba, PR, Brazil
[8] ILAPEO, Grad Program Implant Dent, Dept Orthodont, Curitiba, PR, Brazil
[9] Pontificia Univ Catolica Parana PUCPR, Dept Mechatron Control & Automat, Prod & Syst Engn, Curitiba, PR, Brazil
[10] Soc Ensino Tecn Ensitec, Curitiba, PR, Brazil
[11] Res Ctr Sao Leopoldo Mand Dent, Dent Surg, Curitiba, PR, Brazil
[12] ILAPEO, Curitiba, PR, Brazil
[13] Neodent Osseointegrated Implants, Curitiba, PR, Brazil
[14] Noodent Osscointegrated Implants, Dept Res Dev & Innovat, Curitiba, PR, Brazil
关键词
osteotomy; performance testing; dental implants; tribology; BONE CELL VIABILITY; HEAT-PRODUCTION; CERAMIC DRILLS; CORTICAL BONE; WEAR; OSTEOTOMY; SITE; STERILIZATION; DEFORMATION; TEMPERATURE;
D O I
10.1097/ID.0000000000000645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study evaluated cutting efficiency (CE) and linear wear of dental implant drills after 450 standardized osteotomies on bovine ribs. Diamond-like carbon-coated steel drills (SG), acid-treated steel drills (EG), and ceramic drills (ZG) were divided into 6 subgroups according to the number of uses. Materials and Methods: A robot-controlled program performed systematic instrumentation, timing, axial loading, and managed feed rate. CE was recorded in a polyurethane resin blank and end wear (VBBmax) was analyzed under stereo microscopy. Results: After osteotomies in beef ribs, CE for the phi 2.0-mm drill decreased 10.2% in SG and 10.9% in ZG; for the phi 3.0-mm drill, CE decreased 30.6% in SG, 8.5% in ZG, and improved in EG. The greatest wear occurred in O2.0-mm drills; ZG drills (phi 3.0 mm) exhibited only edge frittering, as confirmed on scanning electron microscopy. Conclusion: After 50 exposures to mechanical loads, steel and ceramic drills lost CE. Whereas cutting and thermal performance improved in experimental drills, the phi 2.0-mm drill exhibited the most signs of wear proportional to use. These findings suggest that, with the methodology employed, the life of these drills exceeds 50 osteotomies.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 50 条
  • [41] Comparative Evaluation of the Surface Hardness of Different Esthetic Restorative Materials: An In Vitro Study
    Samuel, Anoop
    Raju, Rinsa
    Sreejith, K. B.
    Kalathil, Binitha M.
    Nenavath, Deepthi
    Chaitra, V. S.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 124 - 128
  • [42] Comparative Effects of Different Abrasives on Surface Roughness of Dental Materials: An In Vitro Study
    Ludovichetti, Francesco Saverio
    Lucchi, Patrizia
    Bernardelle, Marta
    Signoriello, Anna Giulia
    Pezzato, Luca
    Bertolini, Rachele
    Gallo, Matteo
    Mazzoleni, Sergio
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [43] Accuracy and efficiency of robotic dental implant surgery with different human-robot interactions: An in vitro study
    Xu, Zonghe
    Xiao, Yanjun
    Zhou, Lin
    Lin, Yanjun
    Su, Endian
    Chen, Jiang
    Wu, Dong
    JOURNAL OF DENTISTRY, 2023, 137
  • [44] In vitro evaluation of surface cleaning methods in two different implant defect angulations: a pilot study
    Ozkan Karaca, Ebru
    Tunar, Ogul Leman
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2021, 35 (01) : 560 - 566
  • [45] Comparative Analysis of Surface Finishing for Different Cutting Strategies of Parts Made from POM C
    Panc, Nicolae
    Contiu, Glad
    Bocanet, Vlad
    ADVANCES IN MANUFACTURING ENGINEERING AND MATERIALS, ICMEM 2018, 2019, : 324 - 332
  • [46] Comparative analysis on flexible supporting technology of different types of expansive soil cutting slope in the south and the north of China
    Yang, H. P.
    Lin, J. S.
    Xiao, J.
    UNSATURATED SOIL MECHANICS-FROM THEORY TO PRACTICE, 2016, : 855 - 860
  • [47] Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study
    ELsyad, Moustafa Abdou
    Agha, Nora Nory
    Habib, Ahmed Ali
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1040 - 1048
  • [48] Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Kirita, Tadaaki
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 471 - 476
  • [49] In Vitro Microbiological Bacterial Seal Analysis of the Implant/Abutment Connection in Morse Taper Implants: A Comparative Study Between 2 Abutments
    Deconto, Marco Antonio
    Salvoni, Alexander D'Alvia
    Wassall, Thomaz
    IMPLANT DENTISTRY, 2010, 19 (02) : 158 - 166
  • [50] A Comparative In Vitro Study on Heat Generation with Static Guided and Conventional Implant Bed Preparation Using Stainless Steel Twist Drills and a Standardized Bovine Model
    Tur, Dino
    Tian, Zhiwei
    Giannis, Katharina
    Unger, Ewald
    Mittlboeck, Martina
    Rausch-Fan, Xiaohui
    Strbac, Georg D.
    MATERIALS, 2025, 18 (06)