Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study

被引:13
|
作者
Sugiura, Tsutomu [1 ]
Yamamoto, Kazuhiko [1 ]
Horita, Satoshi [1 ]
Murakami, Kazuhiro [1 ]
Kirita, Tadaaki [1 ]
机构
[1] Nara Med Univ, Dept Oral & Maxillofacial Surg, 840 Shijo Cho, Kashihara, Nara 6348522, Japan
基金
日本学术振兴会;
关键词
Bone density; dental implants; torque; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; DENTAL IMPLANTS; THICKNESS; MICROMOTION; DENSITY; DESIGN; REGIONS; HYBRID; STRAIN;
D O I
10.4103/ccd.ccd_788_18
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: The purposes of this study were to investigate the primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement and to examine the relationship between insertion torque value (ITV) and implant displacement. Materials and Methods: Four different polyurethane bone models consisted of low-density or low-to-medium-density cancellous bone with or without a cortical bone layer. A total of 120 cylindrical and tapered implants were placed into bone blocks (n = 15 in each group), and the ITV was measured. A lateral load of 15 N was applied to the top of the abutment, and implant displacement was recorded. Results: Implant displacement was significantly affected by cancellous bone density and to a lesser degree by cortical bone thickness. The displacement of tapered implants was significantly smaller than that of cylindrical implants in the presence of cortical bone. However, both implant groups showed similar ITV in the low-density cancellous bone model with the cortical bone layer. There was a correlation between ITV and displacement in the cylindrical and tapered implants. However, no correlation was observed between ITV and displacement within each bone type. Conclusions: Implant stability depended mainly on the bone type, whereas implant design had a limited influence on primary stability. The use of tapered implants may be advantageous for improving primary stability in patients with low-density cancellous bone only when crestal cortical bone exists. The same ITV of cylindrical and tapered implants did not necessarily represent similar primary stability in the bone type.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 50 条
  • [1] Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
    Bilhan, Hakan
    Bilmenoglu, Caglar
    Urgun, Aliye Ceren
    Ates, Gokcen
    Bural, Canan
    Cilingir, Altug
    Geckili, Onur
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1036 - 1040
  • [2] Primary Stability of a Hybrid Implant Compared with Tapered and Cylindrical Implants in an Ex Vivo Model
    Toyoshima, Takeshi
    Tanaka, Hideaki
    Ayukawa, Yasunori
    Howashi, Miori
    Masuzaki, Tomohiro
    Kiyosue, Takahiro
    Koyano, Kiyoshi
    Nakamura, Seiji
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (05) : 950 - 956
  • [3] Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study
    Degidi, Marco
    Daprile, Giuseppe
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 334 - 337
  • [4] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    PLOS ONE, 2024, 19 (05):
  • [5] Reliability and Correlation of Different Devices for the Evaluation of Primary Implant Stability: An In Vitro Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Peleg, Maia
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2021, 14 (19)
  • [6] Primary Stability of Conventionally Tapered Versus Reverse Tapered Body Shift Implants Under Varying Bone Support Conditions—An In-Vitro Study
    Jeremy Pitman
    Véronique Christiaens
    Jan Cosyn
    Maarten Glibert
    Journal of Medical and Biological Engineering, 2022, 42 : 429 - 435
  • [7] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333
  • [8] In Vitro Evaluation of the Primary Stability of Short Implants in Different Surgical Techniques
    Kucukguven, Meric Bilgic
    Topaloglu, Goknur
    Isikhan, Selen Yilmaz
    Tosun, Emre
    Saysel, Mustafa Yigit
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (04) : 700 - 706
  • [9] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: An in-vitro study
    Rismanchian M.
    Afshari M.
    Afshari, Mojtaba (Afshari.m1989@gmail.com), 1600, Inderscience Publishers (34): : 319 - 333
  • [10] The evaluation of implant stability measured by resonance frequency analysis in different bone types
    Sargolzaie, Naser
    Samizade, Sarah
    Arab, Hamidreza
    Ghanbari, Habibollah
    Khodadadifard, Leila
    Khajavi, Amin
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2019, 45 (01) : 29 - 33