Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study

被引:13
|
作者
Sugiura, Tsutomu [1 ]
Yamamoto, Kazuhiko [1 ]
Horita, Satoshi [1 ]
Murakami, Kazuhiro [1 ]
Kirita, Tadaaki [1 ]
机构
[1] Nara Med Univ, Dept Oral & Maxillofacial Surg, 840 Shijo Cho, Kashihara, Nara 6348522, Japan
基金
日本学术振兴会;
关键词
Bone density; dental implants; torque; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; DENTAL IMPLANTS; THICKNESS; MICROMOTION; DENSITY; DESIGN; REGIONS; HYBRID; STRAIN;
D O I
10.4103/ccd.ccd_788_18
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: The purposes of this study were to investigate the primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement and to examine the relationship between insertion torque value (ITV) and implant displacement. Materials and Methods: Four different polyurethane bone models consisted of low-density or low-to-medium-density cancellous bone with or without a cortical bone layer. A total of 120 cylindrical and tapered implants were placed into bone blocks (n = 15 in each group), and the ITV was measured. A lateral load of 15 N was applied to the top of the abutment, and implant displacement was recorded. Results: Implant displacement was significantly affected by cancellous bone density and to a lesser degree by cortical bone thickness. The displacement of tapered implants was significantly smaller than that of cylindrical implants in the presence of cortical bone. However, both implant groups showed similar ITV in the low-density cancellous bone model with the cortical bone layer. There was a correlation between ITV and displacement in the cylindrical and tapered implants. However, no correlation was observed between ITV and displacement within each bone type. Conclusions: Implant stability depended mainly on the bone type, whereas implant design had a limited influence on primary stability. The use of tapered implants may be advantageous for improving primary stability in patients with low-density cancellous bone only when crestal cortical bone exists. The same ITV of cylindrical and tapered implants did not necessarily represent similar primary stability in the bone type.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 50 条
  • [31] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [32] Comparative In Vitro Evaluation of the Primary Stability in D3 Synthetic Bone of Two Different Shapes and Pitches of the Implant Threads
    Fanali, Stefano
    Tumedei, Margherita
    Pignatelli, Pamela
    Lucchese, Alessandra
    Inchingolo, Francesco
    Piattelli, Adriano
    Iezzi, Giovanna
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [33] Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study
    Moehlhenrich, S. C.
    Heussen, N.
    Elvers, D.
    Steiner, T.
    Hoelzle, F.
    Modabber, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (12) : 1514 - 1520
  • [34] Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study
    Barbera-Millan, Javier
    Larrazabal-Moron, Carolina
    Jose Eneiso-Ripoll, Juan
    Perez-Pevida, Esteban
    Chavarri-Prado, David
    Dolores Gomez-Adrian, Maria
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (03): : E361 - E367
  • [35] Primary Stability of Implants Placed at Different Angulations in Artificial Bone
    Kashi, Ajay
    Gupta, Bhumija
    Malmstrom, Hans
    Romanos, Georgios E.
    IMPLANT DENTISTRY, 2015, 24 (01) : 92 - 95
  • [36] The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
    Ni, Ming
    Mei, Jiong
    Li, Kun
    Niu, Wenxin
    Zhang, Ming
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [37] The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
    Ming Ni
    Jiong Mei
    Kun Li
    Wenxin Niu
    Ming Zhang
    BioMedical Engineering OnLine, 17
  • [38] Low Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study
    Lee, Sang-Hoon
    Yun, Pil-Young
    Yi, Yang-Jin
    Kim, Young-Kyun
    Lee, Hyo-Jung
    Jo, Deuk-Won
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (05) : 556 - 563
  • [39] Evaluation of primary stability of implants in bovine bone defects models
    Minji Kim
    Jae-Hyun Lee
    Hyo-seon Kim
    Su Young Lee
    Scientific Reports, 15 (1)
  • [40] Influence of different implant materials on the primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    Yang, Yi-Hsin
    Wu, Chao-Yi
    Lan, Ting-Hsun
    Liu, Pao-Hsin
    Chang, Hong-Po
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (12): : 673 - 678