Comparative Analysis of Cutting Efficiency and Surface Maintenance Between Different Types of Implant Drills: An In Vitro Study

被引:4
|
作者
Hochscheidt, Celso Joao [1 ,2 ]
Shimizu, Roberto Hideo [3 ,4 ,5 ]
Andrighetto, Augusto Ricardo [6 ,7 ,8 ]
Pierezan, Rodrigo [9 ,10 ]
Thome, Geninho [11 ,12 ,13 ]
Salatti, Rafael [14 ]
机构
[1] ILAPEO, Implant Dent, Curitiba, PR, Brazil
[2] Clin Top Odontol, Rua Coronel Bittencourt 618, BR-84010290 Ponta Grossa, PR, Brazil
[3] Univ Estadual Paulista UNESP, Orthodont, Araraquara, SP, Brazil
[4] Masters Program Orthodont, Curitiba, PR, Brazil
[5] ILAPEO, Dept Orthodont, Curitiba, PR, Brazil
[6] Univ Sao Paulo, Orthodont, Sao Paulo, SP, Brazil
[7] ILAPEO, Grad Program Orthodont, Dept Orthodont, Curitiba, PR, Brazil
[8] ILAPEO, Grad Program Implant Dent, Dept Orthodont, Curitiba, PR, Brazil
[9] Pontificia Univ Catolica Parana PUCPR, Dept Mechatron Control & Automat, Prod & Syst Engn, Curitiba, PR, Brazil
[10] Soc Ensino Tecn Ensitec, Curitiba, PR, Brazil
[11] Res Ctr Sao Leopoldo Mand Dent, Dent Surg, Curitiba, PR, Brazil
[12] ILAPEO, Curitiba, PR, Brazil
[13] Neodent Osseointegrated Implants, Curitiba, PR, Brazil
[14] Noodent Osscointegrated Implants, Dept Res Dev & Innovat, Curitiba, PR, Brazil
关键词
osteotomy; performance testing; dental implants; tribology; BONE CELL VIABILITY; HEAT-PRODUCTION; CERAMIC DRILLS; CORTICAL BONE; WEAR; OSTEOTOMY; SITE; STERILIZATION; DEFORMATION; TEMPERATURE;
D O I
10.1097/ID.0000000000000645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study evaluated cutting efficiency (CE) and linear wear of dental implant drills after 450 standardized osteotomies on bovine ribs. Diamond-like carbon-coated steel drills (SG), acid-treated steel drills (EG), and ceramic drills (ZG) were divided into 6 subgroups according to the number of uses. Materials and Methods: A robot-controlled program performed systematic instrumentation, timing, axial loading, and managed feed rate. CE was recorded in a polyurethane resin blank and end wear (VBBmax) was analyzed under stereo microscopy. Results: After osteotomies in beef ribs, CE for the phi 2.0-mm drill decreased 10.2% in SG and 10.9% in ZG; for the phi 3.0-mm drill, CE decreased 30.6% in SG, 8.5% in ZG, and improved in EG. The greatest wear occurred in O2.0-mm drills; ZG drills (phi 3.0 mm) exhibited only edge frittering, as confirmed on scanning electron microscopy. Conclusion: After 50 exposures to mechanical loads, steel and ceramic drills lost CE. Whereas cutting and thermal performance improved in experimental drills, the phi 2.0-mm drill exhibited the most signs of wear proportional to use. These findings suggest that, with the methodology employed, the life of these drills exceeds 50 osteotomies.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 50 条
  • [31] Comparative analysis of the efficiency of gas grafting reaction of different types of Hanji with palmitoyl chloride
    Choi K.-H.
    Lee K.S.
    Lee J.-H.
    Lee M.-K.
    Ryu J.-Y.
    Palpu Chongi Gisul/Journal of Korea Technical Association of the Pulp and Paper Industry, 2019, 51 (03): : 90 - 97
  • [32] Comparative study of surface electromyography of masticatory muscles in patients with different types of bruxism
    Lan, Kai-Wen
    Jiang, Liu-Lin
    Yan, Ying
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (20) : 6876 - 6889
  • [33] Comparative study of surface electromyography of masticatory muscles in patients with different types of bruxism
    Kai-Wen Lan
    Liu-Lin Jiang
    Ying Yan
    World Journal of Clinical Cases, 2022, (20) : 6876 - 6889
  • [34] Evaluation of Different Procedures for Titanium Dental Implant Surface Decontamination-In Vitro Study
    Jordan, Ante
    Smojver, Igor
    Budimir, Ana
    Gabric, Dragana
    Vuletic, Marko
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [35] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    DIAGNOSTICS, 2024, 14 (13)
  • [36] Replication Efficiency of Influenza A Virus H9N2: A Comparative Analysis Between Different Origin Cell Types
    Lebas, Nima Zarrin
    Shahsavandi, Shahla
    Mohammadi, Ashraf
    Ebrahimi, Mohammad Majid
    Bakhshesh, Mehran
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2013, 6 (09)
  • [37] A Comparative Evaluation of the Tensile Bond Strength of Cement-retained Restorations on Implant Abutments Subjected to Different Surface Treatments: An In vitro Study
    Jayaswal, Amrita
    Singh, Rashika
    Srivastava, Shitij
    Shekhar, Abhinav
    Bhatia, Love Kumar
    ADVANCES IN HUMAN BIOLOGY, 2024, 14 (02) : 107 - 111
  • [38] Plasma of Argon Affects the Earliest Biological Response of Different Implant Surfaces: An In Vitro Comparative Study
    Canullo, L.
    Genova, T.
    Tallarico, M.
    Gautier, G.
    Mussano, F.
    Botticelli, D.
    JOURNAL OF DENTAL RESEARCH, 2016, 95 (05) : 566 - 573
  • [39] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [40] A Comparative Study On Different Types Of PV Modules and Their Optimization for Increasing The Efficiency Part-I
    Nanda, Gayatri
    Dash, Ritesh
    Swain, Sarat Chandra
    Kumar, Rajesh
    2016 SECOND INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE & COMMUNICATION TECHNOLOGY (CICT), 2016, : 406 - 409