3D catheter reconstruction in HDR prostate brachytherapy for pre-treatment verification using a flat panel detector

被引:9
|
作者
Smith, Ryan L. [1 ,2 ]
Haworth, Annette [2 ,3 ]
Panettieri, Vanessa [1 ]
Millar, Jeremy L. [1 ,2 ,4 ]
Franich, Rick D. [2 ]
机构
[1] Alfred Hosp, Alfred Hlth Radiat Oncol, Melbourne, Vic 3004, Australia
[2] RMIT Univ, Sch Sci, Melbourne, Vic 3000, Australia
[3] Univ Sydney, Sch Phys, Camperdown, NSW 2006, Australia
[4] Monash Univ, Cent Clin Sch, Melbourne, Vic 3004, Australia
关键词
HDR brachytherapy; Pre-treatment imaging; Pre-treatment verification; Prostate; Flat panel detector; RATE AFTERLOADING BRACHYTHERAPY; DOSE-RATE BRACHYTHERAPY; ISOCENTRIC C-ARM; SEED RECONSTRUCTION; CANCER; MOVEMENT; DISPLACEMENT; GUIDELINES; FRACTIONS; ALGORITHM;
D O I
10.1016/j.ejmp.2017.06.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: High dose rate prostate brachytherapy is a widely-practiced treatment, delivering large conformal doses in relatively few treatment fractions. Inter-and intra-fraction catheter displacements have been reported. Unrecognized displacement can have a significant impact on dosimetry. Knowledge of the implant geometry at the time of treatment is important for ensuring safe and effective treatment. In this work we demonstrate a method to reconstruct the catheter positions pre-treatment, using a 'shift' imaging technique, and perform registration with the treatment plan for verification relative to the prostate. Methods: Two oblique 'shift' images were acquired of a phantom containing brachytherapy catheters, representing the patient immediately pre-treatment. Using a back projection approach, the catheter paths were reconstructed in 3D and registered with the planned catheter paths. The robustness of the reconstruction and registration process was investigated as a function of phantom rotation. Catheter displacement detection was performed and compared to known applied displacements. Results: Reconstruction of the implant geometry in 3D immediately prior to treatment was achieved. A mean reconstruction uncertainty of 0.8 mm was determined for all catheters with a mean registration uncertainty of 0.5 mm. A catheter displacement detection threshold of 2.2 mm was demonstrated. Catheter displacements were all detected to within 0.5 mm of the applied displacements. Conclusion: This technique is robust and sensitive to assess catheter displacements throughout the implant volume. This approach provides a method to detect, in 3D, changes in catheter positions relative to the prostate. The method has sufficient sensitivity to enable clinically significant decisions immediately prior to treatment delivery. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 50 条
  • [21] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [22] Audit to analyse the role of pre-treatment verification in 3D CT planning for NSCLC
    Raj, S.
    Gilligan, D.
    Harden, S. V.
    LUNG CANCER, 2007, 57 : S8 - S8
  • [23] 3D Monte Carlo-based treatment planning evaluation of intracavitary HDR balloon catheter brachytherapy
    Lerma, F
    Le, Y
    Kelley, J
    Arthur, D
    Williamson, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1953 - 1953
  • [24] 3D Dosimetric Verification of Ir-192 HDR Brachytherapy Source Irradiation
    Pierquet, M.
    Oldham, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [25] End-to-end verification of 3D printed applicators for HDR skin brachytherapy
    Dewit, B.
    De Brabandere, M.
    Nulens, A.
    Christiaens, M.
    Crijns, W.
    Depuydt, T.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S12 - S14
  • [26] Treatment Verification in Prostate Brachytherapy Patients Using Electromagnetic Tracking Integrated in An HDR/BT Afterloader
    Kolkman-Deurloo, I.
    Heerden Van, L.
    Paassen Van, R.
    Schiphof-Godart, J.
    Christianen, M.
    Mens, J.
    Franckena, M.
    Maenhout, M.
    Rijnsdorp, R.
    Luthart, L.
    Hoogeman, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E869 - E870
  • [27] Treatment verification in high dose rate brachytherapy using a realistic 3D printed head phantom and an imaging panel
    van Wagenberg, Teun
    Fonseca, Gabriel Paiva
    Voncken, Robert
    van Beveren, Celine
    van Limbergen, Evert
    Lutgens, Ludy
    Vanneste, Ben G. L.
    Berbee, Maaike
    Reniers, Brigitte
    Verhaegen, Frank
    BRACHYTHERAPY, 2023, 22 (02) : 269 - 278
  • [28] Quality Control of Tandem-And-Ovoid HDR Brachytherapy Using Pre-Treatment CT Scout Images
    Chen, X.
    Kim, C.
    Wilson, J.
    Fan, J.
    Ariaratnam, L.
    Lockamy, V.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [29] Experimental verification of 3D detector response compensation using the OSEM reconstruction method
    Blinder, S
    Celler, A
    Wells, RG
    Thomson, D
    Harrop, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2174 - 2178
  • [30] 3D ultrasound-supported HDR brachytherapy in prostate cancer - local relapses
    Dankwart, R.-O.
    Kurek, R.
    Buhleier, T.
    Tselis, N.
    Anagnostopoulos, G.
    Baltas, D.
    Zamboglou, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 117 - 118