3D catheter reconstruction in HDR prostate brachytherapy for pre-treatment verification using a flat panel detector

被引:9
|
作者
Smith, Ryan L. [1 ,2 ]
Haworth, Annette [2 ,3 ]
Panettieri, Vanessa [1 ]
Millar, Jeremy L. [1 ,2 ,4 ]
Franich, Rick D. [2 ]
机构
[1] Alfred Hosp, Alfred Hlth Radiat Oncol, Melbourne, Vic 3004, Australia
[2] RMIT Univ, Sch Sci, Melbourne, Vic 3000, Australia
[3] Univ Sydney, Sch Phys, Camperdown, NSW 2006, Australia
[4] Monash Univ, Cent Clin Sch, Melbourne, Vic 3004, Australia
关键词
HDR brachytherapy; Pre-treatment imaging; Pre-treatment verification; Prostate; Flat panel detector; RATE AFTERLOADING BRACHYTHERAPY; DOSE-RATE BRACHYTHERAPY; ISOCENTRIC C-ARM; SEED RECONSTRUCTION; CANCER; MOVEMENT; DISPLACEMENT; GUIDELINES; FRACTIONS; ALGORITHM;
D O I
10.1016/j.ejmp.2017.06.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: High dose rate prostate brachytherapy is a widely-practiced treatment, delivering large conformal doses in relatively few treatment fractions. Inter-and intra-fraction catheter displacements have been reported. Unrecognized displacement can have a significant impact on dosimetry. Knowledge of the implant geometry at the time of treatment is important for ensuring safe and effective treatment. In this work we demonstrate a method to reconstruct the catheter positions pre-treatment, using a 'shift' imaging technique, and perform registration with the treatment plan for verification relative to the prostate. Methods: Two oblique 'shift' images were acquired of a phantom containing brachytherapy catheters, representing the patient immediately pre-treatment. Using a back projection approach, the catheter paths were reconstructed in 3D and registered with the planned catheter paths. The robustness of the reconstruction and registration process was investigated as a function of phantom rotation. Catheter displacement detection was performed and compared to known applied displacements. Results: Reconstruction of the implant geometry in 3D immediately prior to treatment was achieved. A mean reconstruction uncertainty of 0.8 mm was determined for all catheters with a mean registration uncertainty of 0.5 mm. A catheter displacement detection threshold of 2.2 mm was demonstrated. Catheter displacements were all detected to within 0.5 mm of the applied displacements. Conclusion: This technique is robust and sensitive to assess catheter displacements throughout the implant volume. This approach provides a method to detect, in 3D, changes in catheter positions relative to the prostate. The method has sufficient sensitivity to enable clinically significant decisions immediately prior to treatment delivery. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:121 / 131
页数:11
相关论文
共 50 条
  • [41] Determination of 3D ultrasound catheter localization accuracy for high dose rate prostate brachytherapy treatment planning
    Wong, E
    Fenster, A
    Chan, W
    Surry, K
    Smith, W
    Taylor, I
    Lewis, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1734 - 1734
  • [42] Intraluminal HDR brachytherapy in esophageal carcinoma: Ultrasound assisted 3D treatment planning
    Fabrini, MG
    Gennai, A
    Perrone, F
    Rossi, M
    Lazzeri, M
    Cionini, L
    TUMORI, 2001, 87 (04) : S103 - S103
  • [43] Robust 3D Reconstruction Using HDR-Based SLAM
    Yeh, Chia-Hung
    Lin, Min-Hui
    IEEE ACCESS, 2021, 9 : 16568 - 16581
  • [44] Robust 3D Reconstruction Using HDR-Based SLAM
    Yeh, Chia-Hung
    Lin, Min-Hui
    IEEE Access, 2021, 9 : 16568 - 16581
  • [45] Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction
    Lee, Junghoon
    Kuo, Nathanael
    Deguet, Anton
    Dehghan, Ehsan
    Song, Danny Y.
    Burdette, Everette C.
    Prince, Jerry L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 5011 - 5027
  • [46] Towards real-time, personalized breast HDR brachytherapy treatment using 3D printing technology
    Poulin, E.
    Gardi, L.
    Fenster, A.
    Pouliot, J.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S62 - S63
  • [47] 3D conformal HDR brachytherapy and external beam irradiation combined with temporary androgen deprivation in the treatment of localized prostate cancer
    Martin, T
    Röddiger, S
    Kurek, R
    Dannenberg, T
    Eckart, O
    Kolotas, C
    Heyd, R
    Rogge, B
    Baltas, D
    Tunn, U
    Zamboglou, N
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (01) : 35 - 41
  • [48] 3D interstitial HDR brachytherapy combined with 3D external beam radiotherapy and androgen deprivation for prostate cancer -: Preliminary results
    Martin, T
    Hey-Koch, S
    Strassmann, G
    Kolotas, C
    Baltas, D
    Rogge, B
    Röddiger, S
    Vogt, HG
    Heyd, R
    Dannenberg, T
    Kurek, R
    Tunn, U
    Zamboglou, N
    STRAHLENTHERAPIE UND ONKOLOGIE, 2000, 176 (08) : 361 - 367
  • [49] Automated Catheter Segmentation using 3D Ultrasound Images in High-Dose-Rate Prostate Brachytherapy
    Hu, Zoe
    Brastianos, Harry
    Ungi, Tamas
    Pinter, Csaba
    Olding, Tim
    Korzeniowski, Martin
    Fichtinger, Gabor
    MEDICAL IMAGING 2021: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11598
  • [50] TUNING AND VALIDATION OF THE NEW RADCALC 3D MONTE CARLO BASED PRE-TREATMENT PLAN VERIFICATION TOOL
    Giada, Sceni
    Andrea, Botti
    Matteo, Orlandi
    Daniele, Lambertini
    Domenico, Finocchiaro
    Adriana, Barani
    Valentina, Bertolini
    Valeria, Trojani
    Roberto, Sghedoni
    Mauro, Iori
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (06)