Reliability of the first eye and second eye in frequency doubling technology perimetry

被引:3
|
作者
Mukai, S
Tsukamoto, H
Iwase, A
Mishima, HK
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Ophthalmol & Visual Sci, Minami Ku, Hiroshima 7348551, Japan
[2] Tajimi Municipal Hosp, Dept Ophthalmol, Tajimi, Japan
关键词
first eye; frequency doubling technology; reliability; second eye;
D O I
10.1007/s10384-004-0222-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the reliability of the perimetry results of the first eye and the second eye with frequency doubling technology (FDT). Methods: The subjects were 328 residents who underwent the C-20-5 mode of FDT at a city in central Japan. FDT perimetry was always performed first in the right eye and then in the left eye without any time between tests. When more than 33% fixation loss or false-positive error was detected, the result was judged unreliable. Results: Of the 328 subjects, the bilateral perimetry results were reliable in 255 subjects (77.7%), the unilateral results were reliable in 57 (17.4%), and there was not a reliable result in either eve in 16 (4.9%) subjects. Of the 57 subjects whose unilateral result was unreliable, the result of the second eye was unreliable in 50 (88%) subjects, and the result of the first eve was unreliable in 7 (12%). This difference in the reliability between the first eve and second eve was significant (P < 0.001). There were no differences in the age, sex, visual acuity, refractive error, test duration, or number of glaucoma suspects between the two groups whose unilateral result was unreliable in the first eye or the second eye. Conclusions: The FDT perimetry result of the second eye was less reliable than that of the first eye.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [1] Reliability of the First Eye and Second Eye in Frequency Doubling Technology Perimetry
    Satoshi Mukai
    Hidetoshi Tsukamoto
    Aiko Iwase
    Hiromu K Mishima
    Japanese Journal of Ophthalmology, 2005, 49 : 417 - 419
  • [2] Frequency Doubling Perimetry and the detection of eye disease in the community.
    Mansberger, SL
    Spry, PGD
    Fortune, B
    Eke, T
    Johnson, CA
    Cioffi, GA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S87 - S87
  • [3] Relative hypersensitivity in healthy eye by frequency doubling perimetry in patients with severely damaged contralateral eye
    Fujimoto, N
    Zhang, DW
    Minowa, K
    Hanawa, T
    Miyauchi, O
    Adachi-Usami, E
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (06) : 794 - 794
  • [4] Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening
    Najiya Sundus Kadavath Meethal
    Johan J. M. Pel
    Deepmala Mazumdar
    Rashima Asokan
    Manish Panday
    Johannes van der Steen
    Ronnie George
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 1277 - 1287
  • [5] Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening
    Meethal, Najiya Sundus Kadavath
    Pel, Johan J. M.
    Mazumdar, Deepmala
    Asokan, Rashima
    Panday, Manish
    van der Steen, Johannes
    George, Ronnie
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (06) : 1277 - 1287
  • [6] Frequency doubling technology (FDT) perimetry
    Johnson, CA
    Fingeret, M
    Iwase, A
    GLAUCOMA DIAGNOSIS STRUCTURE AND FUNCTION, 2004, : 109 - 117
  • [7] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [8] Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry
    Casson, R
    James, B
    Rubinstein, A
    Ali, H
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) : 360 - 362
  • [9] Frequency doubling technology perimetry in normal children
    Quinn, Laurel M.
    Gardiner, Stuart K.
    Wheeler, David T.
    Newkirk, Michelle
    Johnson, Chris A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 983 - 989
  • [10] Association between frequency doubling perimetry (FDP) and standard automated perimetry: The Los Angeles Latina Eye Study (LALES)
    Tong, LT
    Ying-Lai, M
    Francis, B
    Varma, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46