摘要
Purpose: To compare the reliability of the perimetry results of the first eye and the second eye with frequency doubling technology (FDT). Methods: The subjects were 328 residents who underwent the C-20-5 mode of FDT at a city in central Japan. FDT perimetry was always performed first in the right eye and then in the left eye without any time between tests. When more than 33% fixation loss or false-positive error was detected, the result was judged unreliable. Results: Of the 328 subjects, the bilateral perimetry results were reliable in 255 subjects (77.7%), the unilateral results were reliable in 57 (17.4%), and there was not a reliable result in either eve in 16 (4.9%) subjects. Of the 57 subjects whose unilateral result was unreliable, the result of the second eye was unreliable in 50 (88%) subjects, and the result of the first eve was unreliable in 7 (12%). This difference in the reliability between the first eve and second eve was significant (P < 0.001). There were no differences in the age, sex, visual acuity, refractive error, test duration, or number of glaucoma suspects between the two groups whose unilateral result was unreliable in the first eye or the second eye. Conclusions: The FDT perimetry result of the second eye was less reliable than that of the first eye.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [21] Variability components of standard automated perimetry and frequency-doubling technology perimetry
    Spry, PGD
    Johnson, CA
    McKendrick, AM
    Turpin, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (06) : 1404 - 1410
  • [22] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [23] Recovery of Reliability by Retest After a 5-Minute Interval in Frequency Doubling Technology Perimetry
    Hidetoshi Tsukamoto
    Satoshi Mukai
    Aiko Iwase
    Hiromu K Mishima
    Japanese Journal of Ophthalmology, 2006, 50 : 380 - 382
  • [24] Recovery of reliability by retest after a 5-minute interval in frequency doubling technology perimetry
    Tsukamoto, Hidetoshi
    Mukai, Satoshi
    Iwase, Aiko
    Mishima, Hiromu K.
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2006, 50 (04) : 380 - 382
  • [25] Spatial relationship of defects in frequency doubling technology perimetry and standard achromatic perimetry
    Pascual, JP
    Sample, PA
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U489 - U489
  • [26] Evaluation of Frequency-Doubling Technology Perimetry as a Means of Screening for Glaucoma and Other Eye Diseases Using the National Health and Nutrition Examination Survey
    Boland, Michael V.
    Gupta, Priya
    Ko, Fang
    Zhao, Di
    Guallar, Eliseo
    Friedman, David S.
    JAMA OPHTHALMOLOGY, 2016, 134 (01) : 57 - 62
  • [27] Evaluation of frequency doubling technology perimetry to screen for glaucoma and other eye diseases: the 2005-2008 National Health and Nutrition Examination Survey
    Zhao, Di
    Boland, Michael V.
    Ko, Fang
    Gupta, Priya
    Guallar, Eliseo
    Friedman, David S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [28] Rarebit perimetry and frequency doubling technology in patients with ocular hypertension
    Corallo, G.
    Iester, M.
    Scotto, R.
    Calabria, G.
    Traverso, C. E.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (02) : 205 - 211
  • [29] The influence of learning effect on frequency doubling technology perimetry (Matrix)
    Contestabile, Maria Teresa
    Perdicchi, Andrea
    Amodeo, Stefano
    Recupero, Vincenzo
    Recupero Santi, Maria
    JOURNAL OF GLAUCOMA, 2007, 16 (03) : 297 - 301
  • [30] Frequency-doubling threshold Perimetry in predicting glaucoma in a population-based study - The Beijing eye study
    Wang, Ya Xing
    Xu, Liang
    Zhang, Rong Xiu
    Jonas, Jost B.
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (10) : 1402 - 1406