Reliability of the first eye and second eye in frequency doubling technology perimetry

被引:3
|
作者
Mukai, S
Tsukamoto, H
Iwase, A
Mishima, HK
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Ophthalmol & Visual Sci, Minami Ku, Hiroshima 7348551, Japan
[2] Tajimi Municipal Hosp, Dept Ophthalmol, Tajimi, Japan
关键词
first eye; frequency doubling technology; reliability; second eye;
D O I
10.1007/s10384-004-0222-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the reliability of the perimetry results of the first eye and the second eye with frequency doubling technology (FDT). Methods: The subjects were 328 residents who underwent the C-20-5 mode of FDT at a city in central Japan. FDT perimetry was always performed first in the right eye and then in the left eye without any time between tests. When more than 33% fixation loss or false-positive error was detected, the result was judged unreliable. Results: Of the 328 subjects, the bilateral perimetry results were reliable in 255 subjects (77.7%), the unilateral results were reliable in 57 (17.4%), and there was not a reliable result in either eve in 16 (4.9%) subjects. Of the 57 subjects whose unilateral result was unreliable, the result of the second eye was unreliable in 50 (88%) subjects, and the result of the first eve was unreliable in 7 (12%). This difference in the reliability between the first eve and second eve was significant (P < 0.001). There were no differences in the age, sex, visual acuity, refractive error, test duration, or number of glaucoma suspects between the two groups whose unilateral result was unreliable in the first eye or the second eye. Conclusions: The FDT perimetry result of the second eye was less reliable than that of the first eye.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [31] Impact of cataract on the results of frequency-doubling technology perimetry
    Tanna, AP
    Abraham, C
    Lai, J
    Shen, J
    OPHTHALMOLOGY, 2004, 111 (08) : 1504 - 1507
  • [32] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [33] Frequency doubling technology perimetry for neuro-ophthalmological diseases
    Johnson, CA
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (10) : 1232 - 1233
  • [34] Normal pediatric thresholds using frequency doubling technology perimetry
    Quinn, LM
    Wheeler, DT
    Gardiner, SK
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [35] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09): : 808 - 811
  • [36] Influence of test reliability on the screening performance of frequency-doubling perimetry
    Heeg, GP
    Jansonius, NM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (03) : 585 - 587
  • [37] Impact of tear metrics on the reliability of perimetry in patients with dry eye
    Sagara, Hideto
    Sekiryu, Tetsuju
    Imaizumi, Kimihiro
    Shintake, Hiroaki
    Sugiyama, Urara
    Maehara, Hiroki
    PLOS ONE, 2019, 14 (09):
  • [38] Comparison of frequency doubling technology and Swedish interactive technology algorithm perimetry.
    Moya, FJ
    Shafranov, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S285 - S285
  • [39] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [40] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    Scientific Reports, 12