Impact of measurement setup and test load on the accuracy of harmonic current emission measurements

被引:0
|
作者
Blanco, Ana-Maria [1 ]
Gelleschus, Ronny [1 ]
Meyer, Jan [1 ]
Schegner, Peter [1 ]
机构
[1] Tech Univ Dresden, Inst Elect Power Syst & High Voltage Engn, Dresden, Germany
关键词
measurement; harmonic emission; non-linear loads; accuracy;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to measure the harmonic current emission of equipment in accordance with IEC standards, a measurement setup (voltage source, measurement equipment) with a specified accuracy and reproducibility is required. One possibility to verify its accuracy is the measurement of a set of reference loads with known harmonic emission and a comparison of measured and calculated values. However, laboratory measurements of different non-linear loads have shown that some loads can considerably affect the behavior of the measurement setup. The main objective of this paper is to identify in a systematic way the impact of different voltage sources, measurement equipment and loads on the accuracy of the harmonic current measurements. The paper also identifies the different factors which have considerable impact on the measurement results and evaluates the suitability of a system verification based on reference loads.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [41] Quantifying the Impact of Varying Inductive Burden When Inductive Current Transformers Are Used for Harmonic Current Measurements for Grid Code Compliance
    Murray, Ruan
    de Kock, Jan A.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [42] Polysilicon fatigue test-bed monitoring based on the 2nd harmonic of the device current measurement
    Ferraris, E
    Fassi, I
    De Masi, B
    Del Sarto, M
    [J]. 2005 International Conference on MEMS, NANO and Smart Systems, Proceedings, 2005, : 55 - 60
  • [43] Analysis of the impact caused by low voltage customers harmonic generation in the distribution grid by a harmonic three-phase load flow based on the current summation
    Tostes, MEDL
    Bezerra, UH
    Silva, RDS
    Carvalho, CCM
    Muller, E
    [J]. 2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 803 - 808
  • [44] A Test of the Cognitive Load Hypothesis: Investigating the Impact of Number of Nonverbal Cues Coded and Length of Coding Session on Observer Accuracy
    La France, Betty H.
    Heisel, Alan D.
    Beatty, Michael J.
    [J]. COMMUNICATION REPORTS, 2007, 20 (01) : 11 - 23
  • [45] Impact of radiation on the wall heat load at a test bench gas turbine combustion chamber: Measurements and CFD simulation
    Dannecker, R.
    Noll, B.
    Hase, M.
    Krebs, W.
    Schildmacher, K. -U
    Koch, R.
    Aigner, M.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 4, PTS A AND B, 2007, : 1311 - 1321
  • [46] The method of minimizing the impact of local residual electrostatic charge on dimensional measurement accuracy in atomic force microscopy measurements
    Sikora, Andrzej
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (09)
  • [47] Analysis of the measurement uncertainty associated with 1/R extrapolation of radiated emission measurements on an Open Area Test Site (OATS)
    Gisin, F
    Pantic-Tanner, Z
    [J]. 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - SYMPOSIUM RECORD, VOLS 1 AND 2, 1998, : 137 - 140
  • [48] An ion current intensity measurement device in visible light emission measurements of the interaction of slow, highly charged ion with solid surfaces
    Zhao, Hong-yun
    Su, Hong
    Xu, Qiu-mei
    Guo, Yi-pan
    Kong, Jie
    Qian, Yi
    Yang, Zhi-hu
    [J]. XXVIII INTERNATIONAL CONFERENCE ON PHOTONIC, ELECTRONIC AND ATOMIC COLLISIONS (ICPEAC), 2014, 488
  • [49] MEASUREMENT OF IMPACT LOAD BY USING AN INVERSE ANALYSIS TECHNIQUE - (COMPARISON OF METHODS FOR ESTIMATING THE TRANSFER-FUNCTION AND ITS APPLICATION TO THE INSTRUMENTED CHARPY IMPACT TEST)
    INOUE, H
    ISHIDA, H
    KISHIMOTO, K
    SHIBUYA, T
    [J]. JSME INTERNATIONAL JOURNAL SERIES I-SOLID MECHANICS STRENGTH OF MATERIALS, 1991, 34 (04): : 453 - 458
  • [50] Measurement and control of current/voltage waveforms of microwave transistors using a harmonic load-pull system for the optimum design of high efficiency power amplifiers
    Barataud, D
    Blache, F
    Mallet, A
    Bouysse, PP
    Nebus, JM
    Villotte, JP
    Obregon, J
    Verspecht, J
    Auxemery, P
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (04) : 835 - 842