Impact of measurement setup and test load on the accuracy of harmonic current emission measurements

被引:0
|
作者
Blanco, Ana-Maria [1 ]
Gelleschus, Ronny [1 ]
Meyer, Jan [1 ]
Schegner, Peter [1 ]
机构
[1] Tech Univ Dresden, Inst Elect Power Syst & High Voltage Engn, Dresden, Germany
关键词
measurement; harmonic emission; non-linear loads; accuracy;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to measure the harmonic current emission of equipment in accordance with IEC standards, a measurement setup (voltage source, measurement equipment) with a specified accuracy and reproducibility is required. One possibility to verify its accuracy is the measurement of a set of reference loads with known harmonic emission and a comparison of measured and calculated values. However, laboratory measurements of different non-linear loads have shown that some loads can considerably affect the behavior of the measurement setup. The main objective of this paper is to identify in a systematic way the impact of different voltage sources, measurement equipment and loads on the accuracy of the harmonic current measurements. The paper also identifies the different factors which have considerable impact on the measurement results and evaluates the suitability of a system verification based on reference loads.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [22] An in-house-built thermally stimulated current measurement setup: Strontium titanate as a test system
    Lakshminarayanan, B
    Akbar, S
    Wang, C
    Alim, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (08): : 4830 - 4834
  • [23] Assessments for the Impact of Harmonic Current Distortion of Non Linear Load In Power System Harmonics
    Abu Bakar, M. I.
    [J]. 2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 224 - 229
  • [24] The Impact of Small Non-linear Load Operation on Accuracy of the Intelligent Measurement System
    Belany, Pavol
    Bolf, Andrej
    Novak, Marek
    Roch, Marek
    [J]. 2018 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE), 2018, : 247 - 252
  • [25] Experimental test of PMU measurement errors and the impact on load model parameter identification
    Zhang, Xinran
    Lu, Chao
    Lin, Junjie
    Wang, Ying
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (20) : 4593 - 4604
  • [26] CRUDE AND PROTEIN NITROGEN BASES FOR PROTEIN MEASUREMENT AND THEIR IMPACT ON CURRENT TESTING ACCURACY
    BARBANO, DM
    LYNCH, JM
    [J]. JOURNAL OF DAIRY SCIENCE, 1992, 75 (11) : 3210 - 3217
  • [27] Evaluation of the Influence of Distortion and Measurement Accuracy on the Load Current Observer Based on Artificial Neural Network
    Martinovich, Miroslav, V
    Zaev, Ilya, V
    Belova, Irina A.
    Skolota, Vladimir A.
    [J]. 2019 20TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM 2019), 2019, : 421 - 427
  • [28] Linearity measurements of Si/SiGe heterojunction bipolar transistor using a large signal network analyzer with an harmonic load-pull setup
    Blanchet, F.
    Pache, D.
    Giry, A.
    El Yaagoubi, M.
    Barataud, D.
    Nebus, J. M.
    [J]. PRIME 2006: 2ND CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONIC AND ELECTRONICS, PROCEEDINGS, 2006, : 477 - +
  • [29] Measurement Validation for the Extension of Emission Measurements in Alternative Test Sites Above 1 GHz
    Menssen, Benjamin
    Brech, Henrik
    Garbe, Heyno
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (04) : 1274 - 1281
  • [30] The Impact of Phototherapy on the Accuracy of Transcutaneous Bilirubin Measurements in Neonates: Optimal Measurement Site and Timing
    Ho, Shau-Ru
    Lin, Yu-Chen
    Chen, Chi-Nien
    [J]. DIAGNOSTICS, 2021, 11 (09)