Analysis of the impact caused by low voltage customers harmonic generation in the distribution grid by a harmonic three-phase load flow based on the current summation

被引:1
|
作者
Tostes, MEDL [1 ]
Bezerra, UH [1 ]
Silva, RDS [1 ]
Carvalho, CCM [1 ]
Muller, E [1 ]
机构
[1] Fed Univ Para, Elect Engn & Comp Dept, BR-66059 Belem, Para, Brazil
关键词
current summation method; harmonic load flow analysis; power quality; total harmonic distortion;
D O I
10.1109/TDC.2004.1432485
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article accomplishes an evaluation of the harmonic impacts caused in the distribution grid by the secondary distribution grid customers using a developed three-phase harmonic load flow algorithm. The algorithm is based on the current summation method and incorporates the concept of PV buses in the load flow solution to make the proposed methodology adequate to treat with distributed generation connected to the low voltage distribution grid. A real case study of a distribution feeder with 92 transformers of different capacities and different types of load is presented. Measurements were carried out in 15 transformers strategically selected so as to provide a representative sample of the harmonic injection profile of the feeder.
引用
收藏
页码:803 / 808
页数:6
相关论文
共 50 条
  • [1] Theory Analysis of Harmonic Current Generation and Harmonic Current Extraction of Three-phase Grid-connected Inverter
    Sun, Shaohua
    Ben, Hongqi
    Li, Yingge
    Wang, Leyi
    Yu, Shuai
    [J]. 2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA), 2015, : 2724 - 2729
  • [2] Three-phase harmonic load flow method
    Chang, CY
    Teng, JH
    [J]. IEEE ICIT' 02: 2002 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 839 - 844
  • [3] Multiple-frequency three-phase load flow for harmonic analysis
    Lin, WM
    Zhan, TS
    Tsay, MT
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (02) : 897 - 904
  • [4] Bivariate stochastic model of current harmonic analysis in the low voltage distribution grid
    Iqbal, Muhammad Naveed
    Kutt, Lauri
    Daniel, Kamran
    Jarkovoi, Marek
    Asad, Bilal
    Shabbir, Noman
    [J]. PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2021, 70 (02) : 190 - 206
  • [5] Three-phase harmonic load flow in frequency and time domains
    de Saá, MAML
    García, JU
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2003, 150 (03): : 295 - 300
  • [6] An analysis of three-phase low-harmonic rectifiers applying the third-harmonic current injection
    Pejovic, P
    Janda, Z
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (03) : 397 - 407
  • [7] Three-phase low-harmonic rectifier based on third harmonic current injection with passive circuit
    Li, Xiaoqing
    Chen, Guozhu
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2475 - 2480
  • [8] Harmonic Current Suppression for Three Phase PV Generation System under Unbalanced Grid Voltage
    Shou, Ting
    Wang, Huidong
    Zhu, Tieming
    Zhu, Lianhuan
    Wang, Qianggang
    Lou, Xiaoxuan
    Wang, Jiajia
    Zhou, Niancheng
    [J]. 2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [9] Impact of current high order harmonic to core losses of three-phase distribution transformer
    Digalovski, Mihail
    Najdenkoski, Krste
    Rafajlovski, Goran
    [J]. 2013 IEEE EUROCON, 2013, : 1525 - 1529
  • [10] The Impact of Harmonic Current Flow on Additional Power Losses in Low Voltage Distribution Networks
    Neagu, Bogdan Constantin
    Georgescu, Gheorghe
    Ivanov, Ovidiu
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2016), 2016, : 719 - 722