Development of a new oscillometric blood pressure measurement system

被引:17
|
作者
Moraes, JCTB [1 ]
Cerulli, M [1 ]
Ng, PS [1 ]
机构
[1] Univ Sao Paulo, Escola Politecn, Sao Paulo, Brazil
来源
关键词
D O I
10.1109/CIC.1999.826009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new blood pressure measurement system was developed based on the oscillometric method using a controlled linear deflation technique. The system was structured in order to make several tasks independent and specialized, thus allowing for future punctual developments. An oscillometric signal data base was formed according to the standard ANSI/AAMI/SP10-1992, using the manual auscultatory method as a reference to determine measurement techniques to be used. The correlation among several quantities such as reference blood pressure measurements, characteristic ratios age, weight, height and arm circumference size, was studied. A new strategy to obtain systolic mean and diastolic pressures was oscillometric pulse envelope, depending on parameters such as actual cuff pressure, mean pressure, pulse amplitude and arm circumference size. Mean differences of about -1,49 and 0,61 and standard deviations of 5,11 and 5,89 mmHg were obtained for systolic and diastolic pressure measurements, respectively. Moreover a comparative study with a commercial equipment was performed, with a simulator.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [21] Algorithm of oscillometric blood pressure measurement applied on microcontroller
    Angyal, David
    Vagner, Aniko
    Juhasz, Istvan
    2018 IEEE INTERNATIONAL CONFERENCE ON FUTURE IOT TECHNOLOGIES (FUTURE IOT), 2018,
  • [22] Oscillometric blood pressure measurement: Description of the method used
    Wonka, F
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 1 - 7
  • [23] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272
  • [24] Errors of oscillometric blood pressure measurement as predicted by simulation
    Raamat, Rein
    Talts, Jaak
    Jagomaegi, Kersti
    Kivastik, Jana
    BLOOD PRESSURE MONITORING, 2011, 16 (05) : 238 - 245
  • [25] Oscillometric and auscultatory blood pressure measurement in the assessment of blood pressure and target organ damage
    Johansson, Jouni K.
    Puukka, Pauli J.
    Jula, Antti M.
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 6 - 13
  • [26] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [27] Supraorbital artery as an alternative site for oscillometric blood pressure measurement
    Lee, TK
    Egbert, TP
    Westenskow, DR
    JOURNAL OF CLINICAL MONITORING, 1996, 12 (04): : 293 - 297
  • [28] THE EFFECT OF SLEEVED ARMS ON OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT
    HOLLEMAN, DR
    WESTMAN, EC
    MCCRORY, DC
    SIMEL, DL
    JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (06) : 325 - 326
  • [29] Blood pressure measurement Oscillometric devices are good in routine practice
    Nelson, Mark R.
    BRITISH MEDICAL JOURNAL, 2011, 342
  • [30] Comparison of oscillometric blood pressure measurement by two clinical monitors
    Prashanth, G. P.
    INDIAN JOURNAL OF ANAESTHESIA, 2011, 55 (05) : 548 - U125