Errors of oscillometric blood pressure measurement as predicted by simulation

被引:28
|
作者
Raamat, Rein [1 ]
Talts, Jaak [1 ]
Jagomaegi, Kersti [1 ]
Kivastik, Jana [1 ]
机构
[1] Univ Tartu, Dept Physiol, EE-50411 Tartu, Estonia
关键词
accuracy of oscillometric blood pressure measurement; characteristic ratio; computer simulation; modeling; oscillogram; oscillometric amplitude envelope; AMPLITUDE ENVELOPE; CUFF PRESSURE; ARTERY;
D O I
10.1097/MBP.0b013e32834af752
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To study factors affecting the accuracy of oscillometric measurement. Methods By means of a computer-based simulator, a variety of arterial pressure pulses of different shapes and amplitudes were composed as an input signal of the model, whereas cuff volume oscillations were obtained as an output signal. The shape of the artery-cuff pressure/volume relationship was modified. Thereafter, oscillation envelopes were drawn and an estimation of systolic and diastolic pressures was performed by implementing fixed characteristic ratios. The mean arterial pressure was estimated using the maximum oscillation criterion. Altogether, 32 combinations of four affecting factors were studied. Results For the studied range of affecting factors, the induced errors in systolic pressure, diastolic pressure, and mean arterial pressures were 15, 14, and 27mmHg, respectively. Systolic readings moved toward underestimation and diastolic readings moved toward overestimation if pulse pressure increased. Arterial stiffening induced systematic overestimation of the systolic pressure and overestimation or underestimation of the diastolic pressure compared with a normal artery, with errors depending on the interaction of the symmetry and steepness indices of the artery-cuff pressure/volume curve. Errors of mean arterial pressure were proportional to pulse pressure, showing overestimation if stiffness increased and/or arterial pressure pulses became steeper. Conclusion Oscillometric readings of systolic and diastolic pressures are strongly influenced by pulse pressure and the shape of the artery-cuff pressure/volume curve, whereas those of the mean arterial pressure are affected by pulse pressure and both the shape of the artery-cuff pressure/volume curve and the shape of the arterial pulse. Blood Press Monit 16: 238-245 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:238 / 245
页数:8
相关论文
共 50 条
  • [1] THE SOURCES OF ERRORS IN THE OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS
    Juroszek, Barbara
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2008, 15 (04) : 539 - 549
  • [2] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patel, K
    Brook, R
    [J]. BLOOD PRESSURE MONITORING, 2001, 6 (03) : 145 - 147
  • [3] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patek, K
    Brook, R
    [J]. JOURNAL OF HYPERTENSION, 2000, 18 : S55 - S56
  • [4] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    [J]. CIRCULATION, 1969, 40 (4S3) : II43 - &
  • [5] Assessment of Algorithms for Oscillometric Blood Pressure Measurement
    Chen, S.
    Groza, V. Z.
    Bolic, M.
    Dajani, H. R.
    [J]. I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1711 - 1715
  • [6] A Developed Algorithm for Oscillometric Blood Pressure Measurement
    Chen, Min
    Wang, Qun
    Mei, Zhe
    Liu, Zhiwen
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [7] Increasing the Accuracy of Oscillometric Blood Pressure Measurement
    Sutyagina, Anastasiya D.
    Shlyakhotka, Anna V.
    Lyakhova, Ekaterina K.
    [J]. PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 1231 - 1234
  • [8] Personalization of the Oscillometric Blood-Pressure Measurement
    Nagy, P.
    Jobbagy, A.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 885 - 888
  • [9] Oscillometric blood pressure measurement: Time for a rethink?
    Runcie, CJ
    [J]. ANESTHESIA AND ANALGESIA, 1996, 83 (04): : 886 - 887
  • [10] The oscillometric blood pressure measurement - mathematical modeling
    Juroszek, Barbara
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 304 - 307