A Developed Algorithm for Oscillometric Blood Pressure Measurement

被引:0
|
作者
Chen, Min [1 ]
Wang, Qun [1 ]
Mei, Zhe [1 ]
Liu, Zhiwen [1 ]
机构
[1] Beijing Inst Technol, Sch Informat & Elect, Beijing 100081, Peoples R China
关键词
blood pressure; median filter; Gaussian-Fitting; signal quality; normalizaion; catastrophe point;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A developed method to measure blood pressure (BP) based on oscillometric theory is presented in this paper. Estimating mean pressure (MP) during inflation is applied to set a suitable occluded pressure of cuff. In order to simplify the hardware, moving window median filter (MWMF) is used to extract oscillation pulses from cuff signal. Then, Gaussian-Fitting Method (GFM) is introduced to fit the curve of oscillation pulse envelope. Finally, systolic pressure (SP) and diastolic pressure (DP) is calculated in two different ways according to the quality of signal, which is decided by a proposed mechanism of signal quality decision using correlation coefficient. Experiments have proved the algorithm with high precision and accuracy BP results.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Algorithm of oscillometric blood pressure measurement applied on microcontroller
    Angyal, David
    Vagner, Aniko
    Juhasz, Istvan
    2018 IEEE INTERNATIONAL CONFERENCE ON FUTURE IOT TECHNOLOGIES (FUTURE IOT), 2018,
  • [3] A New Algorithm of Blood Pressure Measurement Based on Oscillometric Method
    Luo, Cong
    Li, Tingyu
    Quan, Xiaoli
    Gu, Liangling
    Zhao, Mingfu
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1710 - +
  • [4] STANDARD ALGORITHM OF BLOOD-PRESSURE MEASUREMENT BY THE OSCILLOMETRIC METHOD
    YAMAKOSHI, K
    TANAKA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (02) : 204 - 204
  • [5] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patel, K
    Brook, R
    BLOOD PRESSURE MONITORING, 2001, 6 (03) : 145 - 147
  • [6] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patek, K
    Brook, R
    JOURNAL OF HYPERTENSION, 2000, 18 : S55 - S56
  • [7] STANDARD ALGORITHM OF BLOOD-PRESSURE MEASUREMENT BY THE OSCILLOMETRIC METHOD - REPLY
    YAMAKOSHI, K
    TANAKA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (05) : 599 - 600
  • [8] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    CIRCULATION, 1969, 40 (4S3) : II43 - &
  • [9] Assessment of Algorithms for Oscillometric Blood Pressure Measurement
    Chen, S.
    Groza, V. Z.
    Bolic, M.
    Dajani, H. R.
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1711 - 1715
  • [10] Personalization of the Oscillometric Blood-Pressure Measurement
    Nagy, P.
    Jobbagy, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 885 - 888