A Developed Algorithm for Oscillometric Blood Pressure Measurement

被引:0
|
作者
Chen, Min [1 ]
Wang, Qun [1 ]
Mei, Zhe [1 ]
Liu, Zhiwen [1 ]
机构
[1] Beijing Inst Technol, Sch Informat & Elect, Beijing 100081, Peoples R China
关键词
blood pressure; median filter; Gaussian-Fitting; signal quality; normalizaion; catastrophe point;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A developed method to measure blood pressure (BP) based on oscillometric theory is presented in this paper. Estimating mean pressure (MP) during inflation is applied to set a suitable occluded pressure of cuff. In order to simplify the hardware, moving window median filter (MWMF) is used to extract oscillation pulses from cuff signal. Then, Gaussian-Fitting Method (GFM) is introduced to fit the curve of oscillation pulse envelope. Finally, systolic pressure (SP) and diastolic pressure (DP) is calculated in two different ways according to the quality of signal, which is decided by a proposed mechanism of signal quality decision using correlation coefficient. Experiments have proved the algorithm with high precision and accuracy BP results.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [32] Supraorbital artery as an alternative site for oscillometric blood pressure measurement
    Lee, TK
    Egbert, TP
    Westenskow, DR
    JOURNAL OF CLINICAL MONITORING, 1996, 12 (04): : 293 - 297
  • [33] THE EFFECT OF SLEEVED ARMS ON OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT
    HOLLEMAN, DR
    WESTMAN, EC
    MCCRORY, DC
    SIMEL, DL
    JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (06) : 325 - 326
  • [34] Blood pressure measurement Oscillometric devices are good in routine practice
    Nelson, Mark R.
    BRITISH MEDICAL JOURNAL, 2011, 342
  • [35] Comparison of oscillometric blood pressure measurement by two clinical monitors
    Prashanth, G. P.
    INDIAN JOURNAL OF ANAESTHESIA, 2011, 55 (05) : 548 - U125
  • [36] Comparability of oscillometric to simultaneous auscultatory blood pressure measurement in children
    Ringrose, Jennifer S.
    Alabbas, Abdullah
    Jalali, Afrooz
    Khinda, Harsimran
    Morgan, Catherine
    Yiu, Verna
    Alexander, R. Todd
    Padwal, Raj
    BLOOD PRESSURE MONITORING, 2019, 24 (02) : 83 - 88
  • [37] Oscillometric and Doppler arterial blood pressure measurement in conscious goats
    Szalus-Jordanow, Olga
    Czopowicz, Michal
    Swierk, Anna
    Szpinda, Oktawia
    Garncarz, Magdalena
    Mickiewicz, Marcin
    Moroz, Agata
    Bagnicka, Emilia
    Kaba, Jaroslaw
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2018, 82 (04): : 244 - 248
  • [38] Bayesian fusion algorithm for improved oscillometric blood pressure estimation
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    Rajan, Sreeraman
    Batkin, Izmail
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (11) : 1300 - 1304
  • [39] A New Noise Reduction Method for Oscillometric Blood Pressure Measurement
    Choi, Hyun-Seok
    Myoung, Hyoun-Seok
    Lee, Hyo-Ki
    Park, Ho-Dong
    Lee, Kyoung-Joung
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 270 - +
  • [40] Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs
    Makepeace, Charles
    Macfarlane, Paul
    Deutsch, Julia
    VETERINARY ANAESTHESIA AND ANALGESIA, 2024, 51 (05) : 482 - 490